Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
We studied how the ratio K of the internal to external diameter of gas- and marrow-filled avian long bones follows the biomechanical optima derived for tubular bones with minimum mass designed to fulfil various mechanical requirements. We evaluated radiographs of numerous humeri, femora and tibiotarsi in Corvus corone cornix and Pica pica. The K-values of the gas-filled humerus (K=0.78+/-0.03) and the marrow-filled femur (K=0.79+/-0.02) in Corvus are practically the same, while K of the marrow-filled tibiotarsus (K=0.71+/-0.04) is significantly smaller. The same is true for the gas-filled humerus (K=0.78+/-0.02) and the marrow-filled femur (K=0.77+/-0.02) and tibiotarsus (K=0.67+/-0.05) in Pica. K in Corvus is slightly larger than K in Pica, but the differences are statistically not significant. The standard deviation DeltaK of the tibiotarsi (DeltaK=0.04-0.05) is approximately two times as large as that of the humeri (DeltaK=0.02-0.03) and femora (DeltaK=0.02) in both species. Accepting the assumption of earlier authors that the ratio Q of the marrow to bone density is 0.5, our data show that the marrow-filled tibiotarsi of Corvus and Pica are optimized for stiffness, while the marrow-filled femora are far from any optimum. The relative wall thickness W=1-K of the gas-filled avian humeri studied is much larger than the theoretical optimum W*=1-K*=0.07, and thus these bones are thicker-walled than the optimal gas-filled tubular bone with minimum mass.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jbiomech.2005.06.013 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!