Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Subdiaphragmatic activity and diaphragmatic motion both contribute to inferior wall artifacts in technetium 99m myocardial perfusion single photon emission computed tomography (SPECT).
Methods And Results: We used an anthropomorphic phantom with ventricular wall activity, liver/spleen inserts containing variable Tc-99m activity, and variable vertical (diaphragmatic) motion amplitude. SPECT and transmission scans were obtained on a GE Optima NX camera. Data were processed by use of filtered backprojection or attenuation correction (AC). Resulting myocardial activity maps were analyzed with standardized inferior-anterior and anterior-lateral wall ratios. At a subdiaphragmatic-myocardial activity ratio of 0.5:1, inferior wall attenuation predominates, producing a cold artifact. AC corrects inferior wall activity to the level of the anterior wall irrespective of diaphragmatic motion. At a subdiaphragmatic-myocardial activity ratio of 1:1, inferior wall counts vary widely depending on the proximity of subdiaphragmatic activity to the ventricle. With increasing diaphragmatic amplitude, the overlap of subdiaphragmatic activity and inferior wall worsens, leading to a complex mixture of cold and hot artifacts, not corrected by AC.
Conclusions: Concentration and proximity of subdiaphragmatic Tc-99m activity relative to myocardium comprise a major factor in the nature and severity of inferior wall artifacts. If the subdiaphragmatic Tc-99m concentration is equivalent to that in the myocardium, complex, potentially uninterpretable hot and cold inferior wall artifacts are produced.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.nuclcard.2005.04.010 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!