High mass measurement accuracy is critical for confident protein identification and characterization in proteomics research. Fourier transform ion cyclotron resonance (FTICR) mass spectrometry is a unique technique which can provide unparalleled mass accuracy and resolving power. However, the mass measurement accuracy of FTICR-MS can be affected by space charge effects. Here, we present a novel internal calibrant-free calibration method that corrects for space charge-induced frequency shifts in FTICR fragment spectra called Calibration Optimization on Fragment Ions (COFI). This new strategy utilizes the information from fixed mass differences between two neighboring peptide fragment ions (such as y(1) and y(2)) to correct the frequency shift after data collection. COFI has been successfully applied to LC-FTICR fragmentation data. Mascot MS/MS ion search data demonstrate that most of the fragments from BSA tryptic digested peptides can be identified using a much lower mass tolerance window after applying COFI to LC-FTICR-MS/MS of BSA tryptic digest. Furthermore, COFI has been used for multiplexed LC-CID-FTICR-MS which is an attractive technique because of its increased duty cycle and dynamic range. After the application of COFI to a multiplexed LC-CID-FTICR-MS of BSA tryptic digest, we achieved an average measured mass accuracy of 2.49 ppm for all the identified BSA fragments.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/pr0501057 | DOI Listing |
Int J Mol Sci
December 2024
Proteomics and Metabolomics Unit, Department of Medicine and Surgery, University of Milano-Bicocca, 20900 Monza, Italy.
Matrix Assisted Laser Desorption/Ionisation-Mass Spectrometry Imaging (MALDI-MSI) is a well-established spatial omic technique which enables the untargeted mapping of various classes of biomolecules, including tryptic peptides, directly on tissue. This method relies on the use of matrices for the ionisation and volatilisation of analytes, and α-Cyano-4-hydroxycinnamic acid (CHCA) represents the most widespread matrix for tryptic peptides analysis. However, CHCA also presents certain limitations that foster the quest for novel matrix compounds.
View Article and Find Full Text PDFAnal Chem
January 2025
Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, Indiana 46556, United States.
Intact protein analysis using mass spectrometry (MS) is an important technique to characterize and provide a comprehensive overview of protein complexity. It is also the basis of "top-down" approaches in proteomics to describe the proteoforms of single protein's post-translational modifications (PTMs). MS-based analysis of intact proteins benefits from high-resolution separations prior to electrospray ionization.
View Article and Find Full Text PDFTalanta
January 2025
Institute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, School of Material Science and Chemical Engineering, Ningbo University, Ningbo, 315211, PR China; Zhenhai Institute of Mass Spectrometry, Ningbo, 315211, PR China; School of Material Science and Chemical Engineering, Ningbo University, Ningbo, 315211, PR China. Electronic address:
A robust interface for coupling capillary electrophoresis (CE) to mass spectrometry (MS) was critical to maintain high separation efficiency of CE while achieving high sensitivity of MS. Current interfaces often suffer from problems such as reproducibility and ruggedness. For this purpose, a new polymetallic-coated sheathless interface was developed for the coupling of CE with MS.
View Article and Find Full Text PDFAnal Methods
August 2024
Henan Key Laboratory of Green Chemical Media and Reactions, Ministry of Education, Henan Key Laboratory of Organic Functional Molecule and Drug Innovation, School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang, 453007, P. R. China.
J Chromatogr B Analyt Technol Biomed Life Sci
January 2024
Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, College of Chemistry, Beijing University of Chemical Technology, Beijing 100029, China. Electronic address:
Protein glycosylation research is currently focused on the development of various functionalized materials that can effectively enrich the levels of glycopeptides in samples. However, most of these materials possess limited glycopeptide-specific recognition sites because of large steric hindrance, unsuitable mass transfer kinetics, and relatively low surface areas. Herein, a highly hydrophilic two-dimensional (2-D) metal-organic framework (MOF) nanosheet modified with glutathione (GSH) and l-cysteine (l-Cys) (denoted as Zr-Fc MOF@Au@GC) has been synthesized for efficient glycopeptide enrichment.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!