A new robotic microscope system, called the Frogatron 3000, was developed to collect time-lapse images from arbitrary viewing angles over the surface of live embryos. Embryos are mounted at the center of a horizontal, fluid-filled, cylindrical glass chamber around which a camera with special optics traverses. To hold them at the center of the chamber and revolve them about a vertical axis, the embryos are placed on the end of a small vertical glass tube that is rotated under computer control. To demonstrate operation of the system, it was used to capture time-lapse images of developing axolotl (amphibian) embryos from 63 viewing angles during the process of neurulation and the in-plane kinematics of the epithelia visible at the center of each view was calculated. The motions of points on the surface of the embryo were determined by digital tracking of their natural surface texture, and a least-squares algorithm was developed to calculate the deformation-rate tensor from the motions of these surface points. Principal strain rates and directions were extracted from this tensor using decomposition and eigenvector techniques. The highest observed principal true strain rate was 28 +/- 5% per hour, along the midline of the neural plate during developmental stage 14, while the greatest contractile true strain rate was--35 +/- 5% per hour, normal to the embryo midline during stage 15.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10439-005-3309-2DOI Listing

Publication Analysis

Top Keywords

robotic microscope
8
in-plane kinematics
8
time-lapse images
8
viewing angles
8
true strain
8
strain rate
8
+/- hour
8
multiview robotic
4
microscope reveals
4
reveals in-plane
4

Similar Publications

Pattern architected soft magnetic actuation.

Soft Matter

January 2025

Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology Madras, Chennai, 600036, Tamil Nadu, India.

Bioinspired shape-morphing soft magnetic actuators have potential applications in medicine, robotics, and engineering due to their soft body, untethered control, and infinite degrees of freedom. The shape programming of the soft magnetic actuators (consisting of soft ferromagnetic CI particles in a soft matrix) is an involved task, as it requires a moulding process severely limiting the capability to program complex shapes. The current study explores a shape programming technique that architects the particle pattern configuration in the actuator, mimicking the pattern found in the mould-programmed actuator, thereby eliminating the need for a mould and providing a greater capability of programming complex shapes.

View Article and Find Full Text PDF

New Directions for Ophthalmic OCT - Handhelds, Surgery, and Robotics.

Transl Vis Sci Technol

January 2025

Department of Biomedical Engineering, Duke University, Durham, NC, USA.

The introduction of optical coherence tomography (OCT) in the 1990s revolutionized diagnostic ophthalmic imaging. Initially, OCT's role was primarily in the adult ambulatory ophthalmic clinics. Subsequent advances in handheld form factors, integration into surgical microscopes, and robotic assistance have expanded OCT's utility and impact outside of its initial environment in the adult outpatient ophthalmic clinic.

View Article and Find Full Text PDF

Status in Brain Gliomas Can Be Predicted by the Spherical Mean MRI Technique.

AJNR Am J Neuroradiol

January 2025

Department of Neurosurgery and Neurooncology (M.M., A.B., T.M., D.K., D.N.), First Faculty of Medicine, Charles University and Military University Hospital, Prague, Czech Republic.

Background And Purpose: Diffuse gliomas, a heterogeneous group of primary brain tumors, have traditionally been stratified by histology, but recent insights into their molecular features, especially the mutation status, have fundamentally changed their classification and prognosis. Current diagnostic methods, still predominantly relying on invasive biopsy, necessitate the exploration of noninvasive imaging alternatives for glioma characterization.

Materials And Methods: In this prospective study, we investigated the utility of the spherical mean technique (SMT) in predicting the status and histologic grade of adult-type diffuse gliomas.

View Article and Find Full Text PDF

A unified model for droplet receding contact angles on hydrophobic pillar, pore, and hollowed pillar arrays.

J Colloid Interface Sci

December 2024

Department of Mechanical Engineering (Robotics), Guangdong Technion - Israel Institute of Technology, Shantou, Guangdong 515063, China.

Hypothesis: Current models for receding contact angles of Cassie-Baxter state droplets on textured hydrophobic substrates are applicable only to a specific structural type, e.g., pillar (above which a droplet has isolated contact line and continuous liquid-vapor interface) or pore (continuous contact line and isolated liquid-vapor interface), signifying a lack of universality.

View Article and Find Full Text PDF

Implementation Strategies and Ergonomic Factors in Robot-assisted Microsurgery.

J Robot Surg

January 2025

BG Trauma Center Ludwigshafen, Department for Plastic, Hand and Reconstructive Surgery, Department of Plastic Surgery for the Heidelberg University, Ludwig-Guttmann-Straße 13, 67071, Ludwigshafen, Germany.

Robot-assisted surgery represents a significant innovation in reconstructive microsurgery, providing enhanced precision and reduced surgeon fatigue. This study examines the integration of robotic assistance in a series of 85 consecutive robot-assisted microsurgical (RAMS) operations. It aims to evaluate changes in the integration of RAMS during the implementation phase in a single institution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!