Due to respiration, many tumours in the thorax and abdomen may move as much as 3 cm peak-to-peak during radiation treatment. To mitigate motion-induced irradiation of normal lung tissue, clinics have employed external markers to gate the treatment beam. This technique assumes that the correlation between the external surface and the internal tumour position remains constant inter-fractionally and intra-fractionally. In this work, a study has been performed to assess the validity of this correlation assumption for external surface based gated radiotherapy, by measuring the residual tumour motion within a gating window. Eight lung patients with implanted fiducial markers were studied at the NTT Hospital in Sapporo, Japan. Synchronized internal marker positions and external abdominal surface positions were measured during the entire course of treatment. Stereoscopic imaging was used to find the internal markers in four dimensions. The data were used retrospectively to assess conventional external surrogate respiratory-gated treatment. Both amplitude- and phase-based gating methods were investigated. For each method, three gating windows were investigated, each giving 40%, 30% and 20% duty cycle, respectively. The residual motion of the internal marker within these six gating windows was calculated. The beam-to-beam variation and day-to-day variation in the residual motion were calculated for both gating modalities. We found that the residual motion (95th percentile) was between 0.7 and 5.8 mm, 0.8 and 6.0 mm, and 0.9 and 6.2 mm for 20%, 30% and 40% duty cycle windows, respectively. Five of the eight patients showed less residual motion with amplitude-based gating than with phase-based gating. Large fluctuations (>300%) were seen in the residual motion between some beams. Overall, the mean beam-to-beam variation was 37% and 42% from the previous treatment beam for amplitude- and phase-based gating, respectively. The day-to-day variation was 29% and 34% from the previous day for amplitude- and phase-based gating, respectively. Although gating reduced the total tumour motion, the residual motion behaved unpredictably. Residual motion during treatment could exceed that which might have been considered in the treatment plan. Treatment margins that account for motion should be individualized and daily imaging should be performed to ensure that the residual motion is not exceeding the planned motion on a given day.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/50/16/001DOI Listing

Publication Analysis

Top Keywords

residual motion
36
phase-based gating
16
motion
12
amplitude- phase-based
12
residual
10
gating
10
gated radiotherapy
8
treatment
8
treatment beam
8
external surface
8

Similar Publications

Background: Contamination of sterilized surgical instruments is not a typically suspected source of increased infection rate, especially if no abnormalities in the sterilization process are detected.

Purpose/hypothesis: The purpose of this study was to report increased infection rates after knee ligament reconstructions due to undetectable sterilization process errors leading to residual moisture, not limited to a specific surgical tool. It was hypothesized that (1) residual moisture on surgical tools due to autoclave overloading would not be detected by autoclave self-diagnostics, chemical and biological tests, or organoleptic assessment and (2) this kind of contamination may elevate infection rates, especially in knee intra-articular reconstruction procedures.

View Article and Find Full Text PDF

Elbow rotation affects the accuracy of rotational formulas: validation of a modified method.

BMC Musculoskelet Disord

January 2025

Pediatric Orthopedic Hospital, Honghui Hospital, Xi'an Jiao tong University, Xi'an, 710000, China.

Background: Supracondylar humerus fractures (SCHFs) are the most common elbow fractures in children and are typically treated with closed reduction and Kirschner pin fixation. However, varying degrees of residual rotational displacement may remain after closed reduction. Several methods exist to assess rotational displacement, but none account for the effect of elbow rotation on the results.

View Article and Find Full Text PDF

Numerical modeling of conventional spin-stop agitation of liquid drug products for automated visual inspection.

Int J Pharm

January 2025

Amgen Inc., Process Development, Manufacturing Technology Advancement (MTA) Group, Thousand Oaks, CA 91320, USA. Electronic address:

The inspection of liquid-filled vials and syringes using automated visual inspection (AVI) machines is a common practice in pharmaceutical production lines. Liquid drug products are typically agitated using a spin-stop motion to detach particles from the interior surface of the containers, thereby maximizing the probability of their detection. A numerical model for an ISO 8362-1 6R glass vial was developed and validated to qualitatively assess the agitation process for a range of motion profiles, liquid drug product properties, and fill volumes.

View Article and Find Full Text PDF

Understanding human behavior and human action recognition are both essential components of effective surveillance video analysis for the purpose of guaranteeing public safety. However, existing approaches such as three-dimensional convolutional neural networks (3D CNN) and two-stream neural networks (2SNN) have computational hurdles due to the significant parameterization they require. In this paper, we offer HARNet, a specialized lightweight residual 3D CNN that is built on directed acyclic graphs and was created expressly to handle these issues and achieve effective human action detection.

View Article and Find Full Text PDF
Article Synopsis
  • Patients with transfemoral amputation often face issues related to socket fit and overuse injuries due to uneven joint stress, which can be improved by using bone-anchored prosthetics that connect directly to the bone.
  • This study investigates the relationship between the alignment of the femur and pelvis and how it impacts hip loading asymmetry during walking, both before and one year after receiving a bone-anchored limb implant.
  • The analysis included 19 participants from a larger group who underwent the surgery, comparing their skeletal alignment and hip motion data collected at two different time points to determine the effects of the implantation on their mobility and joint loading.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!