A self-starting optical pulse source based on mutually coupled optoelectronic oscillators is described. The system employs a phototransistor-based microwave oscillator that is coupled to a fiber cavity optoelectronic oscillator with an intracavity fiber parametric amplifier. It self-starts and exhibits 3 ps pulses at a rate of 10 GHz with extremely low jitter of 30, 29, and 40 fs (for integration bandwidths of 100 Hz-15 kHz, 500 Hz-1 MHz, and 100 Hz-1 MHz, respectively).

Download full-text PDF

Source
http://dx.doi.org/10.1364/ol.30.001623DOI Listing

Publication Analysis

Top Keywords

pulse source
8
source based
8
coupled optoelectronic
8
optoelectronic oscillators
8
intracavity fiber
8
fiber parametric
8
parametric amplifier
8
hz-1 mhz
8
self-starting ultralow-jitter
4
ultralow-jitter pulse
4

Similar Publications

Prehospital Interventions to Reduce Discomfort From Spinal Immobilization in Adult Trauma Patients: A Scoping Review.

J Trauma Nurs

January 2025

Author Affiliations: Department of Community Medicine, Information and Health Decision Sciences, University of Porto, Porto, Portugal (Dr Mota); Health School, Polytechnic Institute of Viseu, Viseu, Portugal (Drs Mota, Santos, and Cunha); Health Sciences Research Unit: Nursing (UICISA: E), Coimbra, Portugal (Drs Mota and Cunha); CINTESIS@RISE - Center for Health Technology and Services Research, University of Porto, Porto, Portugal (Drs Mota and Santos); Academic Clinical Centre of Beiras, Covilhã, Portugal (Drs Mota and Cunha); Abel Salazar Institute of Biomedical Sciences, University of Porto, Porto, Portugal (Drs Melo and Santos); Portugal Centre for Evidence-Based Practice: A Joanna Briggs Institute Centre of Excellence, Coimbra, Portugal (Dr Santos); Hospital São Teotónio, Tondela Viseu Hospital Centre, Viseu, Portugal (Dr Abrantes); Santa Casa da Misericórdia de Seia, Seia, Portugal (Dr Monteiro); and Nursing School of Porto, Porto, Portugal (Dr Santos).

Background: Spinal immobilization, a widely used trauma prehospital intervention, is known to cause discomfort, yet little is known about interventions to reduce this discomfort.

Objective: This scoping review aims to evaluate prehospital interventions to reduce discomfort from spinal immobilization in adult trauma patients.

Method: This scoping review assessed prehospital pharmacological and nonpharmacological interventions to address discomfort from spinal immobilization in adult trauma patients.

View Article and Find Full Text PDF

Aims: To examine the association of a remote monitoring programme (RMP) with all-cause mortality and hospital admissions for heart failure (HF) within the French healthcare system.

Methods And Results: A national-scale, real-world, propensity-weighted cohort study was conducted using the SNDS French database from August 2018 to December 2022 (NCT06312501). Patients receiving standard of care (SoC) were compared with those receiving RMP (Satelia® Cardio, NP Medical).

View Article and Find Full Text PDF

A complementary experimental and computational study on methanol adsorption isotherms of H-ZSM-5.

Phys Chem Chem Phys

January 2025

UK Catalysis Hub, Research Complex at Harwell, Science and Technology Facilities Council, Rutherford Appleton Laboratory, OX11 0FA, UK.

Methanol adsorption isotherms of fresh f-ZSM-5 and steamed s-ZSM-5 (Si/Al ≈ 40) are investigated experimentally at room temperature under equilibrium and by grand canonical Monte Carlo (GCMC) simulations with the aim of understanding the adsorption capacity, geometry and sites as a function of steam treatment (at 573 K for 24 h). Methanol adsorption energies calculated by GCMC are complemented by density functional theory (DFT) employing both periodic and quantum mechanics/molecular mechanics (QM/MM) techniques. Physical and textural properties of f-ZSM-5 and s-ZSM-5 are characterised by diffuse reflectance infrared Fourier transformed spectroscopy (DRIFTS) and N-physisorption, which form a basis to construct models for f-ZSM-5 and s-ZSM-5 to simulate methanol adsorption isotherms by GCMC.

View Article and Find Full Text PDF

To compare the impact of manual right arm blood pressure measurement with computer-controlled blood pressure meter (CCBPM) on the detection rate of hypertension among elderly individuals. This was a cross-sectional study. Elderly residents undergoing routine health check-up in a village in Jiangxi Province from April to June 2024 were enrolled.

View Article and Find Full Text PDF

Introduction: Opioid overdose and blood-borne virus transmission are key health risks for people who inject drugs. Existing study methods that record data on injecting drug risks mostly rely on retrospective self-reporting that, while valid, are limited to being broad and subject to recall bias. The In-The-Moment-Expanded (ITM-Ex) study will evaluate the feasibility and acceptability of multiple novel data collection methods to capture in situ drug injecting data.