The design of an electromagnetic acoustic transducer (EMAT) array device for the inspection of large areas of metallic plate-like structures using the S0 guided wave mode is described. The reasons for using the S0 mode are discussed and it is shown how the choice of mode determines the nature of the EMAT array elements. A novel array construction technique is shown to be necessary whereby the EMAT coils for adjacent elements are overlapped in order to achieve the required element density. Results are presented that illustrate the operation of the device on steel and aluminum plate specimens in the thickness range from 5 to 10 mm. An area of at least 10 m2 can be inspected from a single location. Spurious signals in the results are caused both by the unwanted A0 mode and by S0 sidelobes, the latter occurring at the same radial distance from the array as the genuine S0 signal from a reflector, but in the wrong direction. The signal-to-coherent noise performance of the complete system is determined by the amplitude ratio of the largest genuine S0 signal to the largest spurious signal. This is typically around 30 dB. The sensitivity of the device to artificial defects and genuine corrosion patches is demonstrated and the limitations of its operation are discussed. The feasibility of using the device with the S1 guided wave mode to inspect a 20 mm thick plate is also demonstrated.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/tuffc.2005.1428048 | DOI Listing |
Sensors (Basel)
December 2024
Institute of Fundamental Technological Research, Polish Academy of Sciences, ul. Pawińskiego 5B, 02-106 Warsaw, Poland.
In this paper, we demonstrate that torsional surface elastic waves can propagate along the curved surface of a metamaterial elastic rod (cylinder) embedded in a conventional elastic medium. The crucial parameter of the metamaterial rod is its elastic compliance s44(1)ω, which varies as a function of frequency ω analogously to the dielectric function εω in Drude's model of metals. As a consequence, the elastic compliance s44(1)ω can take negative values s44(1)ω<0 as a function of frequency ω.
View Article and Find Full Text PDFAcad Radiol
January 2025
Department of Orthopedics and Traumatology, Samsun University Faculty of Medicine, Samsun, Turkey (A.E.O.).
Rationale And Objectives: This study aimed to evaluate the efficacy of ultrasound (US)-guided local steroid injection in carpal tunnel syndrome (CTS) using shear wave elastography (SWE).
Materials And Methods: A total of 47 wrists from 41 patients diagnosed with mild to moderate idiopathic CTS, based on clinical and electrophysiological criteria, were enrolled between June and October 2024. All participants underwent US-guided local steroid injection.
J Chem Phys
December 2024
Dipartimento di Fisica Ettore Pancini, Università di Napoli Federico II, Monte S. Angelo, I-80126 Napoli, Italy.
Quantum Monte Carlo (QMC) methods represent a powerful family of computational techniques for tackling complex quantum many-body problems and performing calculations of stationary state properties. QMC is among the most accurate and powerful approaches to the study of electronic structure, but its application is often hindered by a steep learning curve; hence it is rarely addressed in undergraduate and postgraduate classes. This tutorial is a step toward filling this gap.
View Article and Find Full Text PDFUrolithiasis is a multifactorial condition where stone composition is critical in guiding treatment and prevention strategies. Advanced diagnostic techniques, such as infrared spectroscopy, provide precise stone analysis, enabling clinicians to tailor interventions based on specific stone types and associated metabolic abnormalities. Calcium oxalate monohydrate stones often require invasive approaches like percutaneous nephrolithotomy, while uric acid responds well to dissolution therapy.
View Article and Find Full Text PDFJ Am Coll Cardiol
January 2025
Mount Sinai Fuster Heart Hospital, Icahn School of Medicine at Mount Sinai, New York, New York, USA. Electronic address: https://twitter.com/DLBHATTMD.
Background: In patients with ST-segment elevation myocardial infarction (STEMI) and multivessel coronary artery disease, most but not all randomized trials have reported that complete revascularization (CR) offers advantages over culprit vessel-only revascularization. In addition, the optimal timing and assessment methods for CR remain undetermined.
Objectives: The purpose of this study was to identify the optimal revascularization strategy in patients with STEMI and multivessel disease, using a network meta-analysis of randomized controlled trials.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!