The purpose of the study was to evaluate the feasibility of the creation of a percutaneous extrahepatic portacaval shunt (PEPS) in swine by a transjugular approach and to find a suitable stent-graft to use in PEPS. In 12 swine, the extrahepatic portal vein (PV) was entered from the inferior vena cava (IVC) by a needle system introduced from the transjugular approach. A catheter introduced through the transhepatic approach served as a target. Five types of stent-graft consisting of homemade Z stents and a polytetrafluoethylene cover were explored for PEPS creation. Eight animals had follow-up venograms up to 6 weeks or until the shunt became severely stenotic. Gross and histologic examinations were performed after the final follow-up venography. The PV punctures and stent-graft placement were difficult, but the PEPS was established in all animals. In four animals, the stent-graft failed to adequately cover the tract, causing severe hemorrhage. Only two shunts remained patent up to 6 weeks. The other shunts exhibited severe stenosis or occlusion. At gross examination, all shunts traversed the liver parenchyma of the caudate lobe surrounding the IVC. The extravascular PEPS portion was 4 mm to 2 cm long. All shunts entered the PV close to the splenomesenteric junction and exhibited neointimal formation. Shunt stenoses were caused by neointimal hyperplasia and occlusions by a superimposed thrombus. PEPS can be created by the transjugular approach in swine, but only the PV shunt entrance is extrahepatic. None of the tested rigid stent-grafts were suitable for PEPS creation. A short flexible stent-graft with flanged ends is suggested for further exploration.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00270-004-0305-0 | DOI Listing |
Hepatology
January 2025
Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy.
Background Aims: In clinical practice, the reduction of porto-caval pressure gradient (PCPG) following trans-jugular intra-hepatic porto-systemic shunt (TIPS) does not always meet the recommendation of current guidance. We evaluated the impact of different degrees of PCPG reduction, measured at the end of an elective TIPS, on ascites control, recurrence of portal hypertension-related bleeding (PHRB) and survival.
Approach And Results: Cirrhotic patients receiving TIPS for refractory ascites (RA) or for the secondary prophylaxis of PHRB were consecutively enrolled.
Hepatology
January 2025
Department for Gastroenterology, Hepatology, Infectious Diseases and Endocrinology, Hannover Medical School, Hannover, Germany.
Background Aims: Clinically-significant portal hypertension (CSPH) in liver cirrhosis patients can lead to refractory ascites. A transjugular-intrahepatic-portosystemic shunt (TIPS) treats CSPH but may cause overt hepatic encephalopathy (oHE). Our aim was to determine the optimal reduction of the portal pressure gradient (PPG) via TIPS to control ascites without raising oHE risk.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Department of Cardiovascular Medicine, Sendai Kousei Hospital, 1-20 Tsutsumidori-amamiya, Aoba Ward, Sendai, Miyagi 9810914, Japan.
CVIR Endovasc
December 2024
Department of Gastroenterology, Medical University Innsbruck, Anichstrasse 35, Innsbruck, 6020, Austria.
Background: Three patients with portal hypertension and gastrointestinal bleeding due to non-cirrhotic portal vein thrombosis were treated with portal venous recanalization transjugular intrahepatic portosystemic shunt (PVR-TIPS) via a trans-splenic access.
Main Body: A "bottoms-up" retrograde puncture of the right hepatic vein was performed using a re-entry catheter to gain access to the right hepatic vein. In all patients a successful retrograde puncture of the right hepatic vein was achieved, thereby restoring the splenoportal tract.
J Vasc Interv Radiol
December 2024
Department of Interventional Radiology, Zhongshan Hospital, Fudan University; National Clinical Research Center for Interventional Medicine, Zhongshan Hospital, Fudan University; Shanghai Institution of Medical Imaging, Fudan University. Electronic address:
Purpose: To evaluate the consistency and agreement between portal venous pressure measured by fine-needle (F), portal vein catheterization (D), and hepatic vein balloon-occlusion (W) in decompensated cirrhotic patients with intrahepatic venovenous shunts (IHVS).
Materials And Methods: 156 consecutive patients planning to receive transjugular intrahepatic portosystemic shunt in our center were screened for study participation. The F/D/W were assessed for consistency by Pearson coefficient (r), linear regression coefficient (R), and intraclass correlation coefficient (ICC), and for disagreement (error exceeding 20% of D) by Bland-Altman method.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!