There is a substantial list of pre-analytical variables that can alter the analysis of blood-derived samples. We have undertaken studies on some of these issues including choice of sample type, stability during storage, use of protease inhibitors, and clinical standardization. As there is a wide range of sample variables and a broad spectrum of analytical techniques in the HUPO PPP effort, it is not possible to define a single list of pre-analytical standards for samples or their processing. We present here a compendium of observations, drawing on actual results and sound clinical theories and practices. Based on our data, we find that (1) platelet-depleted plasma is preferable to serum for certain peptidomic studies; (2) samples should be aliquoted and stored preferably in liquid nitrogen; (3) the addition of protease inhibitors is recommended, but should be incorporated early and used judiciously, as some form non specific protein adducts and others interfere with peptide studies. Further, (4) the diligent tracking of pre-analytical variables and (5) the use of reference materials for quality control and quality assurance, are recommended. These findings help provide guidance on sample handling issues, with the overall suggestion being to be conscious of all possible pre-analytical variables as a prerequisite of any proteomic study.

Download full-text PDF

Source
http://dx.doi.org/10.1002/pmic.200401245DOI Listing

Publication Analysis

Top Keywords

pre-analytical variables
12
plasma proteome
8
list pre-analytical
8
protease inhibitors
8
hupo plasma
4
proteome project
4
project specimen
4
specimen collection
4
collection handling
4
handling standardization
4

Similar Publications

Article Synopsis
  • * A study involving 277 breast cancer patients examined the effects of WIT, CIT, and FT on the expression of estrogen receptors (ER), progesterone receptors (PgR), and HER2 in surgical specimens compared to preoperative biopsies.
  • * Findings showed that while ER and PgR expressions tended to decrease with longer CIT and FT, only HER2 expression was significantly affected by WIT exceeding 30 minutes, indicating the importance of
View Article and Find Full Text PDF

Objectives: There is a lack of analyte stability data in whole blood (WB). The aim of this study was to determine the allowable delay in WB processing for lactate dehydrogenase (LDH), folate, vitamin B12, iron and phosphate measurement. The stability of LDH, folate and vitamin B12 was also assessed in stored serum at clinically relevant time points.

View Article and Find Full Text PDF

BRAF p.V600E exon 15 hotspot mutation can identify a molecular subgroup of metastatic colorectal cancer (mCRC) patients exhibiting poor prognosis under the conventional chemotherapy regimen. Recently, the chemotherapy-free combination of encorafenib and cetuximab has been approved as the standard of care for previously treated BRAF p.

View Article and Find Full Text PDF
Article Synopsis
  • * A new method utilizing ultra-high-performance liquid chromatography coupled with triple-quadrupole mass spectrometry (UHPLC-MS/MS) allows for efficient GAG extraction and quantification, processing up to 82 samples in one run.
  • * This streamlined process can be completed in approximately 1.5 days, fits standard work shifts, and is precise enough to use GAGs as reliable biomarkers, although it requires specialized knowledge in UHPLC-MS/MS.
View Article and Find Full Text PDF

: The diagnostic accuracy for Parkinson's disease (PD), a synucleinopathy, based on diagnostic criteria is suboptimal. A biomarker for synucleinopathies is pivotal both from a clinical and from a research point of view. CSF a-synuclein has been extensively studied over the past two decades as a candidate biomarker of synucleinopathies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!