Visual and profilometric wear measurements.

Acta Odontol Scand

Department of Dental Biomaterials, College of Dentistry, University of Florida, Gainesville.

Published: April 1992

Wear of composites can be estimated by the degree of marginal discrepancy between the prepared cavity wall and the occlusal margins of composites. Such evaluations are done on casts by comparing and rating the marginal discrepancy with those on standard casts. We analyzed the reliability of this technique on metal and stone specimens. These specimens contained grooves of different width and depth. For the visual comparison we used stone casts of machined standards of known groove depth. We measured the depths of the metal specimens with a profilometer and made stone casts of these original specimens. Using the stone casts of the standards, five dentists estimated the unknown groove depths on the remaining stone casts. These estimates were done under standardized conditions and repeated by each dentist on five different occasions. The results showed that visual depth evaluations of die stone specimens underestimated the depths when compared with the values measured with a profilometer on the original metal models. One investigator gave significantly different (p less than 0.05) groove depth estimates at different occasions.

Download full-text PDF

Source
http://dx.doi.org/10.3109/00016359209012754DOI Listing

Publication Analysis

Top Keywords

stone casts
16
marginal discrepancy
8
stone specimens
8
groove depth
8
casts
6
stone
6
specimens
5
visual profilometric
4
profilometric wear
4
wear measurements
4

Similar Publications

Statement Of Problem: Intraoral scans can be articulated in maximum intercuspal position (MIP) by using an artificial intelligence (AI) based program; however, the impact of edentulous areas on the accuracy of the MIP located using this AI-based program is unknown.

Purpose: The purpose of this in vitro study was to assess the impact of edentulous areas (0, 1, 2, 3, and 4 posterior mandibular teeth) on the accuracy of the MIP located using 3 intraoral scanners (IOSs) and an AI-based program.

Material And Methods: Stone casts articulated in MIP in an articulator were digitized (T710).

View Article and Find Full Text PDF

Purpose: Artificial intelligence (AI) may be used to learn and predict the maxillomandibular relationship, particularly when the number of occluding teeth pairs is insufficient. This study aimed to investigate the feasibility of training a new two-stage coarse-to-fine teeth alignment pipeline AI system in predicting maxillomandibular relationships based on the occlusal morphology of antagonistic teeth.

Methods: Maxillary and mandibular stone casts were collected and scanned at the maximal intercuspal position (MIP).

View Article and Find Full Text PDF

Introduction: With the current surge into digital dentistry, several options are available for clinicians, for example, when providing indirect restorations. There is a need for evidence on the quality of fixed dental prostheses (FDPs) fabricated using either digital or conventional impressions. This study aimed to evaluate the marginal fit of single-crown and three-unit FDP frameworks fabricated from digital and conventional impressions.

View Article and Find Full Text PDF

Objective: This study aimed to compare a direct conventional 3D digital technique vis a vis a hybrid method in measuring palatal volume.

Materials And Methods: Thirty maxillary casts were obtained from the records of patients undergoing orthodontic treatment and pre-conceived boundaries of the palatal vault were marked. Sample was categorised into Group I (Volume estimation using CBCT scan) and Group II (Volume estimation using hybrid method).

View Article and Find Full Text PDF

Direct vs. Indirect Digital Implant Impressions: A Time and Cost Analysis.

Dent J (Basel)

October 2024

Faculdade de Medicina Dentária and INEGI Researcher, Universidade do Porto, 4200-393 Oporto, Portugal.

Background/objectives: This study aimed to compare the cost and time implications for implant-supported prosthesis comparing three digital impression techniques: digitization with an intraoral scanner, digitization of the conventional impression (without dental casts) and digitization of the stone models.

Methods: To assess the time and cost of digital impression techniques on implants, time records on intraoral scans were consulted and three models were created with one, two and six implants to assess extraoral procedures time. Costs were evaluated based on material consumption, time expenditure and operator-related expenses.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!