Hydroxyzine and metabolites as a source of interference in carbamazepine particle-enhanced turbidimetric inhibition immunoassay (PETINIA).

Ther Drug Monit

UF 21 303, Pharmacologie et Toxicologie Analytique, Analyses des Eléments Trace, Fédération de Biochimie, Hôpital Edouard Herriot, Lyon, France.

Published: August 2005

A 32-year-old epileptic patient with a lengthy history of multiple-drug abuse and psychotic disorders was found to have an elevated serum carbamazepine concentration of 40.5 mg/L (therapeutic range 4-12 mg/L) using particle-enhanced turbidimetric inhibition immunoassay (PETINIA). Serum reanalysis by LC-DAD revealed only high hydroxyzine (HDZ) concentration (HDZ = 0.55 mg/L; therapeutic range <0.1 mg/L), suggesting cross-reactivity between HDZ and PETINIA. To confirm this hypothesis, the authors tested 2 commercially available carbamazepine immunoassays, PETINIA and EMIT 2000, for in vitro cross-reactivity with HDZ and 2 HDZ metabolites (cetirizine and norchlorcyclizine). To determine the frequency of this interaction in a clinical setting, 40 sera of 39 patients taking HDZ without carbamazepine were tested by both immunoassays. For some samples, LC-ESI-MS analysis of HDZ metabolites was performed. Additionally, cross-reactivities produced by other benzhydrylpiperazine drugs were evaluated. in vitro, 5 mg of HDZ, cetirizine, and norchlorcyclizine cross-reacted with PETINIA at 85%, 125%, and 66%, respectively. Conversely, EMIT 2000 showed no cross-reactivity. For PETINIA, erroneous carbamazepine concentrations were detected in 35 out of 40 sera of patients taking HDZ. The magnitude of interference correlated moderately with serum HDZ concentrations (Spearman rho coefficient 0.58, P < 0.001), suggesting a major role for the multiple HDZ metabolites (4 serum metabolites were detected by LC-ESI-MS). Furthermore, other benzhydrylpiperazine drugs (eg, oxatomide) showed in vitro cross-reactivity with PETINIA. In conclusion, HDZ and its metabolites cross-react with carbamazepine PETINIA immunoassay, which could significantly affect the correct interpretation of serum carbamazepine concentrations in patients treated with HDZ.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.ftd.0000160718.88822.20DOI Listing

Publication Analysis

Top Keywords

particle-enhanced turbidimetric
8
turbidimetric inhibition
8
inhibition immunoassay
8
immunoassay petinia
8
mg/l therapeutic
8
therapeutic range
8
hydroxyzine metabolites
4
metabolites source
4
source interference
4
interference carbamazepine
4

Similar Publications

: The current gold standards for diagnosing acute kidney injury (AKI) are an increase in serum creatinine and a decrease in urine output, which are inadequate for rapid diagnosis. Neutrophil gelatinase-associated lipocalin (NGAL) is a 25-kDa protein produced and secreted by injured kidney tubule epithelial cells, and can serve as an early urinary biomarker for AKI. ProNephro AKI (NGAL) is an immunoassay for the quantitative determination of NGAL in urine (uNGAL) that recently received FDA clearance.

View Article and Find Full Text PDF

Validation of plasma neutrophil gelatinase-associated lipocalin as a biomarker for diabetes-related acute kidney injury.

Sci Prog

October 2024

Departament of Health Management, Economics and Policy, School of Public Health, Augusta University, Augusta, GA, USA.

Objective: This retrospective study aimed to investigate the correlation between neutrophil gelatinase-associated lipocalin (NGAL) levels and the clinical progression and severity of diabetes-related acute kidney injury (AKI). The quantitative determination of NGAL in plasma on the Beckman Coulter AU480 analyzer was measured using the Bioporto NGAL Test, a particle-enhanced turbidimetric immunoassay with hospitalized patients at an East Central Georgia Medical Center.

Methods: The clinical determination of plasma NGAL included a retrospective cohort study where 45 adult patients were selectively recruited.

View Article and Find Full Text PDF
Article Synopsis
  • A study evaluates a limited sampling strategy (LSS) for estimating the area under the plasma concentration-time curve (AUC) of the immunosuppressant mycophenolic acid (MPA) in kidney transplant patients using two different measurement methods: particle-enhanced turbidimetric inhibition immunoassay (PETINIA) and high-performance liquid chromatography with ultraviolet detection (HPLC-UV).
  • The optimal LSS equation includes three time points (0, 2, and 6 hours), demonstrating high predictive performance and utility in clinical practice.
  • Validation results showed strong correlation and comparable predictive metrics for both measurement methods, indicating that the LSS developed with PETINIA can be effectively applied to HPLC-UV
View Article and Find Full Text PDF

Clinical performance of a particle enhanced turbidimetric immunoassay (PETIA) for detecting fecal calprotectin.

Scand J Clin Lab Invest

October 2024

Department of Gastroenterology, Beijing Friendship Hospital, Capital Medical University, National Clinical Research Center for Digestive Diseases, Beijing Digestive Disease Center, Beijing, China.

Particle-enhanced turbidimetric immunoassay (PETIA) is a new measurement procedure for detecting fecal calprotectin (FC). We aimed to investigate the accuracy and clinical performance of PETIA for FC. We assessed the accuracy of PETIA for FC measurements through concordance analysis, Passing-Bablok regression and Bland-Altman analysis, using enzyme-linked immunosorbent assay (ELISA) as the reference.

View Article and Find Full Text PDF

Background: HIV-1 has well-established mechanisms to disrupt essential pathways in people with HIV, such as inflammation and metabolism. Moreover, diversity of the amino acid sequences in fundamental HIV-1 proteins including Tat and Vif, have been linked to dysregulating these pathways, and subsequently influencing clinical outcomes in people with HIV. However, the relationship between Tat and Vif amino acid sequence variation and specific immune markers and metabolites of the tryptophan-kynurenine (Trp-Kyn) pathway remains unclear.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!