A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intraspinal metalloma resulting in late paraparesis. | LitMetric

Intraspinal metalloma resulting in late paraparesis.

Arch Orthop Trauma Surg

Department of Orthopedic Surgery, Florence Nigthingale Hospital, Abide-i Hürriyet Caddesi no. 290, 80220, Istanbul, Turkey.

Published: July 2005

The metal-related complications caused by orthopedic implants have long been a concern, but these problems have been considered mostly in the field of arthroplasty or internal fixation of fractures. The recent prevalence of spinal instrumentation has evoked a similar concern among spine surgeons. Here, we present a case of intraspinal metallosis adjacent to the pedicular hook occurring after treatment of vertebral fracture by posterior spinal instrumentation and fusion, and causing paraparesis at the 3rd postoperative year. Metallic granulomas can appear around the pedicular hooks as in the reported case. Crevice and fretting corrosion are results at the junctions of rod-screw, rod-hook, transverse connector rod and other connector rods in modular spinal implants. Adequate usage of transpedicular screws may inhibit the occurrence of such a complication. For this reason, further studies are necessary to increase metallic corrosive resistance to inhibit crevice and fretting corrosion.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00402-005-0802-xDOI Listing

Publication Analysis

Top Keywords

spinal instrumentation
8
crevice fretting
8
fretting corrosion
8
intraspinal metalloma
4
metalloma late
4
late paraparesis
4
paraparesis metal-related
4
metal-related complications
4
complications caused
4
caused orthopedic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!