The purpose of this study was to quantify to what extent relative and absolute bladder dose-volume and dose-surface histograms of the planning CT scan were representative for the actual treatment. We used data of 17 patients, who each received 11 repeat CT scans and a planning CT scan. The repeat CT scans were matched on the planning CT scan by the bony anatomy. Clinical treatment plans were used to evaluate the impact of bladder filling changes on the four histogram types. The impact was quantified by calculating for this patient group the correlation coefficient between the planning histogram and the treatment histogram. We found that the absolute dose-surface histogram was the most representative one for the actual treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/50/15/007DOI Listing

Publication Analysis

Top Keywords

representative actual
12
planning scan
12
actual treatment
8
repeat scans
8
absolute relative
4
relative dose-surface
4
dose-surface dose-volume
4
dose-volume histograms
4
histograms bladder
4
bladder representative
4

Similar Publications

Dosimetric comparison of CyberKnife and conventional linac prostate SBRT plans: analysis of the PACE-B Study.

Int J Radiat Oncol Biol Phys

January 2025

The Royal Marsden NHS Foundation Trust, London SM2 5PT, UK; Radiotherapy and Imaging Division, Institute of Cancer Research, London SM2 5NG, UK.

Purpose: In the PACE-B study, a non-randomised comparison of toxicity outcomes between stereotactic body radiotherapy (SBRT) platforms revealed fewer urinary side-effects with CyberKnife (CK) compared to conventional linac (CL) SBRT. This analysis compares baseline characteristics and planning dosimetry between the CK-SBRT and CL-SBRT cohorts in PACE-B, aiming to provide insight into possible reasons for differing toxicity outcomes between the platforms.

Methods: Dosimetric parameters for the surrogate urethra (SU), contoured urethra, bladder, bladder trigone (BT), and rectum were extracted from available CT planning scans of PACE-B SBRT patients.

View Article and Find Full Text PDF

In existing coverage challenges within wireless sensor networks, traditional sensor perception models often fail to accurately represent the true transmission characteristics of wireless signals. In more complex application scenarios such as warehousing, residential areas, etc., this may lead to a large gap between the expected effect of actual coverage and simulated coverage.

View Article and Find Full Text PDF

The lipid content of nine dinoflagellates was analyzed using flow cytometry to compare lipid levels. Additionally, the correlation between lipid content, cell size, and carbon content in dinoflagellates was evaluated using BODIPY 505/515 staining. The flow cytometry side scatter (SSC) effectively represented relative cell size, showing a linear relationship with the equivalent spherical diameter (ESD).

View Article and Find Full Text PDF

Abnormally fertilized embryos are often discarded during in vitro fertilization due to the fact that known chromosomal ploidy abnormalities lead to implantation failure or pregnancy loss. The objective of this study was to determine if pronuclear numeration (PN) observed at fertilization check is representative of the true ploidy status of the subsequent developing blastocyst in order to maximize the number of viable embryos available for infertility patients and increase their chances of conception. Upon successful fertilization, pronuclear numeration was noted, and zygotes were cultured to the blastocyst stage.

View Article and Find Full Text PDF

Background: The reported benefit of poly (ADP-ribose) polymerase inhibitor (PARPi) maintenance in patients with newly diagnosed and platinum (Pt)-sensitive recurrent ovarian cancer (OC) included in randomized clinical trials needs to be corroborated in a less selected population.

Objective: The aim is to increase the evidence on niraparib in a real-world setting.

Methods: This is a retrospective observational study including women with platinum-sensitive relapsed high-grade serous OC who started niraparib maintenance between August 2019 (marketing data, Spain) and May 2022.

View Article and Find Full Text PDF