Background: Atrioventricular plane displacement (AVPD) study by M-mode echocardiography can supply useful clinical information about left ventricular (LV) long-axis function.
Hypothesis: We assessed the hypothesis that AVPD estimation could be used to detect early hypertensive cardiomyopathy.
Methods: The study population included 81 hypertensive patients with normal LV ejection fraction and fractional shortening, and 50 age- and gender-matched healthy controls. By utilizing M-mode and apical views, the following parameters were estimated: early mitral flow peak velocity (E) and deceleration time (DT), peak velocity of late mitral flow (A), A/E ratio, isovolumic relaxation time (IVRT), total AVPD, AVPD motion during atrial systole (At), systolic AVPD (total AVPD-At), and At/total AVPD ratio.
Results: Of 81 hypertensive patients, 16 (19.7%) had a normal (Group 1) and 65 (80.3%) an impaired LV relaxation filling pattern (Group 2). Mean total AVPD-At was significantly lower in Group 2 than in Group 1 (7.1 +/- 2 vs. 10.3 +/- 3 mm, p<0.001) and in Group 1 compared with healthy subjects (10.3 +/- 3 vs. 13.1 +/- 1 mm, p<0.001). Mean At and At/total AVPD were significantly higher in Group 2 than in Group 1 (46.9 +/- 8.6 vs. 37.7 +/- 8.7%, p<0.001), but not in Group 1 compared with healthy subjects (37.7 +/- 8.7 vs. 36 +/- 6%, p>0.05).
Conclusions: Hypertensive patients without overt systolic dysfunction demonstrate LV long-axis systolic dysfunction, while long-axis diastolic dysfunction always coexists with abnormal diastolic filling patterns. This suggests that long-axis systolic dysfunction precedes diastolic dysfunction at the same axis in hypertensive patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6653996 | PMC |
http://dx.doi.org/10.1002/clc.4960280605 | DOI Listing |
Cureus
December 2024
Internal Medicine, Kempegowda Institute of Medical Sciences, Bangalore, IND.
Sepsis-induced cardiomyopathy (SICM) is a life-threatening complication of sepsis characterized by myocardial dysfunction. SICM significantly increases mortality rates in sepsis. Despite its clinical relevance, SICM lacks a unified definition and standardized diagnostic criteria, complicating early identification and treatment.
View Article and Find Full Text PDFThe guide extension-facilitated ostial stenting (GEST) technique uses a guide extension catheter (GEC) to improve stent delivery during primary coronary angioplasty (PCI). GECs are used for stent delivery into the coronary arteries of patients with difficult anatomy due to tortuosity, calcification, or chronic total occlusion (CTO) vessels. Stent and balloon placement has become challenging in patients with increasing lesion complexity due to tortuosity, vessel morphology, length of the lesion, and respiratory movements.
View Article and Find Full Text PDFLeft ventricular assist devices (LVADs) have been used as a bridge to transplantation in patients with advanced heart failure. In this case, LVAD therapy was used as a destination therapy for 16 years, representing the longest documented and continuously ongoing support with the original implanted device.
View Article and Find Full Text PDFFront Endocrinol (Lausanne)
December 2024
Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, United States.
Diabetic cardiomyopathy (DMCM), defined as left ventricular dysfunction in the setting of diabetes mellitus without hypertension, coronary artery disease or valvular heart disease, is a well-recognized entity whose prevalence is certainly predicted to increase alongside the rising incidence and prevalence of diabetes mellitus. The pathophysiology of DMCM stems from hyperglycemia and insulin resistance, resulting in oxidative stress, inflammation, cardiomyocyte death, and fibrosis. These perturbations lead to left ventricular hypertrophy with associated impaired relaxation early in the course of the disease, and eventually culminating in combined systolic and diastolic heart failure.
View Article and Find Full Text PDFBackground: Diagnosis of cardiac amyloidosis (CA) is often missed or delayed due to confusion with other causes of increased left ventricular wall thickness. Conventional transthoracic echocardiographic measurements like global longitudinal strain (GLS) has shown promise in distinguishing CA, but with limited specificity. We conducted a study to investigate the performance of a computer vision detection algorithm in across multiple international sites.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!