Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
An investigation of the fabrication of microporous silicon (MPS) layers as a material for the development of an electrolyte insulator semiconductor (EIS) capacitance sensor has been performed. The goal was to create a high surface area substrate for the immobilisation of biorecognition elements. Structural analysis of MPS layers as a function of key etch parameters, namely implant type (p or n), implant dose, hydrofluoric acid (HF) etch concentration and current density has been performed using scanning electron microscopy (SEM). It was possible to image porous layers with average pore diameter as low as 4 nm. n-type silicon samples had larger pore networks than p-type samples and reducing the silicon resistivity led to a reduction in the pores per microm2. It was found that increasing the HF etch concentration reduced the average pore diameter and increased the pores per microm2. Increasing the current density at which the etch was performed has the same effect. Understanding the effect of these parameters allows the MPS layer to be tuned to match specifications for optimum biocapacity. Different MPS layers were electrically characterised using capacitance-voltage and capacitance-frequency sweeps, in order to determine the effect of porosity on increases in surface area. The measured capacitance increased with increasing pores per microm2. p-type silicon with a boron implant in the back of the wafer, which had been etched in 25% HF in ethanol at a current density of 75 mA/cm2 yielded the highest capacitance signal per unit area. The effect of porosity and pore size on the biocapacity of the samples was also determined. For avidin immobilisation, with pores sizes above 5 nm, as the porosity increased the biocapacity increased. MPS fabricated in p-type silicon with a front and back implant etched in 25% HF at a current density of 25 mA/cm2 was used for the capacitance detection of synthetic oligonucleotides.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bios.2004.09.031 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!