Sixteen subjects exercised at 80-85% of maximal aerobic capacity on a treadmill while wearing a tight-fitting, FRM40-Turbo Powered Air Purifying Respirator (PAPR). The PAPR was powered by a DC power supply to give flow rates of 0%, 30%, 66%, 94%, and 100% of rated maximum blower capacity of 110 L/min. As flow rate was reduced, so was performance time. There was a 20% reduction in performance time as blower flow changed from 100% to 0% of maximum. Significant differences in breathing apparatus comfort and facial thermal comfort were found as flow rate varied. It was concluded that inadequate blower flow rate decreases performance time, facial cooling, and respirator comfort.

Download full-text PDF

Source
http://dx.doi.org/10.1080/15459620591005044DOI Listing

Publication Analysis

Top Keywords

flow rate
12
performance time
12
wearing tight-fitting
8
powered air
8
air purifying
8
purifying respirator
8
blower flow
8
flow
6
exercise performance
4
performance wearing
4

Similar Publications

While the content of subjective (personal) experience is inaccessible to external observers, behavioral proxies can frame the nature of that experience and suggest its cognitive requirements. Directed attention is widely recognized as a feature of animal awareness. This descriptive study used the frequency of gaze shifts in lizards and birds as an indicator of the rate at which the animals change the perceptual segmentation of their ongoing experience.

View Article and Find Full Text PDF

Aims: This study aims to verify the feasibility and safety of percutaneous coronary intervention (PCI) after a distal transradial approach (dTRA) with radial artery occlusion (RAO) recanalization.

Methods: Between July 2018 and January 2022, 30 patients underwent PCI following attempted RAO recanalization via dTRA. Among these cases, the target radial arteries could not be recanalized in five patients, necessitating alternative vascular access.

View Article and Find Full Text PDF

VA-ECOM assisted percutaneous mechanical thrombectomy treatment high-risk pulmonary embolism.

Front Cardiovasc Med

December 2024

Department of Vascular Surgery, The Second Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang, Hunan, China.

Background: Percutaneous mechanical thrombectomy (PMT) is increasingly used in the treatment of intermediate and high-risk acute pulmonary embolism (PE), and the treatment of high-risk PE with the aid of veno-arterial extracorporeal membrane oxygenation (VA-ECMO) has also been reported. However, there are few reports of VA-ECOM-assisted PMT in the treatment of high-risk PE. The purpose of this study is to summarize the data of 11 patients with high-risk PE treated with VA-ECMO assisted PMT, and propose feasible treatment methods for such patients.

View Article and Find Full Text PDF

Mass spectrometry (MS) is a valuable tool that enables label-free analysis and the ability to measure multiple molecules. The atmospheric pressure MS imaging (MSI) method usually requires tedious sample preparation. A simple ionization method with minimal sample preparation is needed for high-throughput analysis.

View Article and Find Full Text PDF

Multiple physiological changes occur during the menstrual cycle; many are attributed to fluctuations in estrogen, luteinizing hormone, follicle-stimulating hormone, and progesterone. These hormones differentially affect the menstrual cycle's follicular, ovulation, and luteal phases. Skin is one of the organs affected by changes in a woman's menstrual cycle.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!