Unusual implication of biopsy forceps in outbreaks of Pseudomonas aeruginosa infections and pseudo-infections related to bronchoscopy.

J Hosp Infect

Service de Réanimation Médicale Assistance Respiratoire, Hôpital Gui de Chauliac, 80 avenue Augustin Fliche, 34295 Montpellier, France.

Published: September 2005

Between January and April 2003, a sudden increase in positive respiratory tract specimens for Pseudomonas aeruginosa was observed in an intensive care unit of the University Teaching Hospital of Montpellier, France. Most of the strains were cultured from bronchoalveolar lavage fluid samples, suggesting that bronchoscopic procedures could be implicated. The relationships between isolates were investigated by antibiotyping and pulsed-field gel electrophoresis. Both phenotypic and molecular markers allowed identification of two consecutive nosocomial outbreaks of respiratory infections related to two different bronchoscopes. These two outbreaks implicated nine and seven patients, respectively. Four of these 16 patients had true infections and recovered with antibiotic therapy. Inspection of both bronchoscopes revealed a damaged internal channel caused by defective biopsy forceps. These defects led to improper cleaning and disinfection of the bronchoscopes despite adherence to all current reprocessing procedures. The two outbreaks were controlled after replacing the inner channels of the bronchoscopes and switching from use of re-usable to disposable biopsy forceps. These outbreaks emphasize the need to establish surveillance procedures for detecting contamination of bronchoscopes, and the importance of recording each endoscopic procedure to facilitate further investigations if needed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhin.2005.01.024DOI Listing

Publication Analysis

Top Keywords

biopsy forceps
12
forceps outbreaks
8
pseudomonas aeruginosa
8
outbreaks
5
bronchoscopes
5
unusual implication
4
implication biopsy
4
outbreaks pseudomonas
4
aeruginosa infections
4
infections pseudo-infections
4

Similar Publications

Purpose: To investigate and compare the feasibility, safety, and clinical outcomes of antegrade and retrograde laparoscopic bilateral inguinal lymphadenectomy for penile cancer.

Methods: We retrospectively analyzed the clinical data of 32 patients with penile cancer admitted between 2018 and 2022. Among them, 17 patients underwent antegrade laparoscopic inguinal lymphadenectomy (ALIL group) and 15 underwent retrograde laparoscopic inguinal lymphadenectomy (RLIL group).

View Article and Find Full Text PDF

Currently, the direct endonasal approach is widely used in endoscopic endonasal surgery (EES) for pituitary neuroendocrine tumor. However, a large posterior septal perforation is inevitable. We routinely utilize a modified para/transseptal approach using the combination of a Killian and a contralateral rescue flap incision (PTSA with K-R incision).

View Article and Find Full Text PDF

Background/aims: Pathological evaluation is crucial for diagnosing biliary lesions and determining appropriate treatment strategies. However, tissue sampling via the transpapillary route can be difficult. In this study, we aimed to assess the efficacy and safety of a novel tapered-tip sheath system for tissue sampling from biliary strictures.

View Article and Find Full Text PDF

Background: Laparoscopic liver resection (LLR) can be challenging due to the difficulty of establishing a retrohepatic tunnel under laparoscopy. Dissecting the third hepatic hilum before parenchymal transection often leads to significant liver mobilization, tumor compression, and bleeding from the short hepatic veins (SHVs). This study introduces a novel technique utilizing the ventral avascular area of the inferior vena cava (IVC), allowing SHVs to be addressed after parenchymal transection, thereby reducing surgical complexity and improving outcomes in in situ LLR.

View Article and Find Full Text PDF

Embryoscopy and targeted embryo biopsy for the management of early abortion.

J Assist Reprod Genet

January 2025

Centro de Asistencia a La Reproducción Humana de Canarias, La Laguna, Santa Cruz de Tenerife, Spain.

Purpose: To evaluate the safety, accuracy, and effectiveness of embryoscopy for the management of early abortion and to test the hypothesis that targeted embryo and chorionic villi sampling avoids maternal cell contamination (MCC) for genetic testing of products of conception (POC).

Methods: This ambispective study included 74 consecutive patients presenting with early abortion. Gestations between 5 and 9 weeks, obtained either spontaneously or through assisted reproductive technologies were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!