Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The utility of programmed ventricular stimulation to predict future arrhythmic events in patients with cardiac sarcoidosis is unknown. Similarly, the long-term benefit of implantable cardioverter-defibrillators (ICDs) in cardiac sarcoidosis has not been established. Thirty-two consecutive patients with cardiac sarcoidosis underwent programmed ventricular stimulation. Patients with spontaneous or inducible sustained ventricular arrhythmias (n = 12) underwent ICD insertion. All study patients were followed for the combined arrhythmic event end point of appropriate ICD therapies or sudden death. Mean length of follow-up to sustained ventricular arrhythmia or sudden death was 32 +/- 30 months. Five of 6 patients (83%) with spontaneous sustained ventricular arrhythmias and 4 of 6 patients (67%) without spontaneous but with inducible sustained ventricular arrhythmias received appropriate ICD therapy. Two of 20 patients (10%) with neither spontaneous nor inducible sustained ventricular arrhythmias experienced sustained ventricular arrhythmias or sudden death. Programmed ventricular stimulation predicted subsequent arrhythmic events in the entire population (relative hazard 4.47, 95% confidence interval [CI] 1.30 to 15.39) and in patients who presented without spontaneous sustained ventricular arrhythmias (relative hazard 6.97, 95% CI 1.27 to 38.27). No patient with an ICD died of a primary arrhythmic event. In patients with spontaneous or inducible sustained ventricular arrhythmias, mean survival from first appropriate ICD therapy to death or cardiac transplant was 60 +/- 46 months, with only 2 patients dying or reaching transplant at study end. In conclusion, programmed ventricular stimulation identifies patients with cardiac sarcoidosis at high risk for future arrhythmic events. ICDs effectively terminate life-threatening arrhythmias in high-risk patients, with significant survival after first appropriate therapy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.amjcard.2005.03.059 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!