A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Characterization of gunpowder samples using time-of-flight secondary ion mass spectrometry (TOF-SIMS). | LitMetric

Characterization of gunpowder samples using time-of-flight secondary ion mass spectrometry (TOF-SIMS).

Forensic Sci Int

National Institute of Standards and Technology, Surface and Microanalysis Science Division, 100 Bureau Drive, Mail Stop 8371, Gaithersburg, MD 20899, USA.

Published: April 2006

Time-of-flight secondary ion mass spectrometry (TOF-SIMS) was utilized to obtain characteristic mass spectra from three different smokeless powders and six different black powder samples. In these mass spectra, peaks indicative of both the organic and inorganic additive constituents in the gunpowders were observed. TOF-SIMS was able to successfully differentiate between the different black and smokeless gunpowder samples analyzed with the aid of principal components analysis (PCA), a multivariate statistical analysis approach often used to reduce the dimensionality of complex data. TOF-SIMS was also used to obtain information about the spatial distribution of the various additives contained within the gunpowder samples. SIMS imaging demonstrated that that the samples could potentially be characterized by their 2-D structure, which varied from sample to sample. These results clearly demonstrate the feasibility of utilizing TOF-SIMS as a tool for the characterization and differentiation of gunpowder samples for general forensic applications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.forsciint.2005.02.036DOI Listing

Publication Analysis

Top Keywords

gunpowder samples
16
time-of-flight secondary
8
secondary ion
8
ion mass
8
mass spectrometry
8
spectrometry tof-sims
8
mass spectra
8
samples
6
tof-sims
5
characterization gunpowder
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!