Objective: To assess the biomechanic effects of wearing a lateral wedge on the knee joint varus moment during gait in elders with and without knee osteoarthritis (OA).

Design: Crossover design whereby subjects walked under 2 different insole conditions: a 0 degrees control wedge and a 6 degrees lateral wedge.

Setting: A gait laboratory with 3-dimensional motion analysis and force platform equipment.

Participants: Thirteen healthy subjects and 13 knee patients with OA.

Interventions: Not applicable.

Main Outcome Measures: Frontal plane angles and moments at the knee and subtalar joints, ground reaction forces, and center of pressure. Moments were derived by using a 3-dimensional inverse dynamics model of the lower extremity.

Results: The 6 degrees lateral wedge significantly reduced knee joint varus moment and increased subtalar joint valgus moment in both groups when compared with no wedge. All patients had a greater knee joint varus moment with a similar subtalar joint valgus moment compared with the people without OA. There were diverse, sometimes reversed effects with the insole among the patients.

Conclusions: The 6 degrees lateral wedge did not consistently reduce the knee joint varus moment in patients with knee OA. The biomechanic indications and limitations of laterally wedged insoles should be confirmed by a larger study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apmr.2004.09.033DOI Listing

Publication Analysis

Top Keywords

knee joint
16
joint varus
16
varus moment
16
subtalar joint
12
lateral wedge
12
degrees lateral
12
knee
9
laterally wedged
8
wedged insoles
8
knee subtalar
8

Similar Publications

Aims: The aim of this study was to perform an incremental cost-utility analysis and assess the impact of differential costs and case volume on the cost-effectiveness of robotic arm-assisted medial unicompartmental knee arthroplasty (rUKA) compared to manual (mUKA).

Methods: Ten-year follow-up of patients who were randomized to rUKA (n = 64) or mUKA (n = 65) was performed. Patients completed the EuroQol five-dimension health questionnaire preoperatively, at three months, and one, two, five, and ten years postoperatively, which was used to calculate quality-adjusted life years (QALY) gained and the incremental cost-effectiveness ratio (ICER).

View Article and Find Full Text PDF

Aims: The Exeter femoral stem has a cemented, polished taper-slip design, and an excellent track record. The current range includes short-length options for various offsets, but less is known about the performance of these stems. The aim of this study was to compare the survival of short-length stems with standard-length Exeter stems.

View Article and Find Full Text PDF

Aims: Prolonged waits for hip and knee arthroplasty have raised questions about the equity of current approaches to waiting list prioritization for those awaiting surgery. We therefore set out to understand key stakeholder (patient and surgeon) preferences for the prioritization of patients awaiting such surgery, in order to guide future waiting list redesign.

Methods: A combined qualitative/quantitative approach was used.

View Article and Find Full Text PDF

Aims: The Clavien-Dindo (CD) classification and Comprehensive Complication Index (CCI) have been validated primarily among general surgical procedures. To date, the validity of these measures has not been assessed in patients undergoing arthroplasty.

Methods: This retrospective cohort study included patients undergoing primary total hip and knee arthroplasty between April 2013 and December 2019.

View Article and Find Full Text PDF

Background: Although stroke patients gain an advantage in gait due to the knee hyperextension that occurs during the stance phase, this situation disrupts the biomechanical structure of the knee and increases the risk of injury to the capsular and ligamentous structures. The aim of this study was to examine the effects of rigid taping on hyperextension control and pelvic kinematics in stroke patients with knee hyperextension during the stance phase of gait.

Research Question: Does rigid taping have an effect on hyperextension control and pelvic kinematics in stroke patients with knee hyperextension?

Methods: Thirty stroke patients aged between 40 and 70 were included in this pre-postintervention study.

View Article and Find Full Text PDF