A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a 3-D, multi-nuclear continuous wave NMR imaging system. | LitMetric

Development of a 3-D, multi-nuclear continuous wave NMR imaging system.

J Magn Reson

Department of Bio-Medical Physics and Bio-Engineering, University of Aberdeen, Foresterhill, Aberdeen AB25 2ZD, UK.

Published: October 2005

The development of a 3-D, multi-nuclear continuous wave NMR imaging (CW-NMRI) system is described and its imaging capability is demonstrated on a range of materials exhibiting extremely short T(2) relaxation values. A variety of radiofrequency resonators were constructed and incorporated into a new gradient and field offset coil assembly, while the overall system design was modified to minimise microphonic noise which was present in an earlier prototype system. The chemically combined (27)Al in a high temperature refractory cement was imaged, and the CW-NMRI system was found to be sensitive to small differences in (27)Al content in these samples. The penetration of (23)Na in salt water into samples of ordinary Portland cement (OPC) was investigated, with enhanced uptake observed for samples with larger pore size distributions. The solid (13)C component in a carbonated cement sample was also imaged, as were the (7)Li nuclei in a sample of powdered Li(2)CO(3). A spatial resolution of 1mm was measured in an image of a rigid polymeric material exhibiting a principal T( *)(2) value of 16.3 micros. Finally, a high-resolution 3-D image of this rigid polymer is presented.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmr.2005.05.022DOI Listing

Publication Analysis

Top Keywords

development 3-d
8
3-d multi-nuclear
8
multi-nuclear continuous
8
continuous wave
8
wave nmr
8
nmr imaging
8
cw-nmri system
8
image rigid
8
system
5
imaging system
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!