The effect of Na+-K+ pump activation on endothelium-dependent relaxation (EDR) and on intracellular Ca2+ concentration ([Ca2+]i) was examined in mouse aorta and mouse aortic endothelial cells (MAECs). The Na+-K+ pump was activated by increasing extracellular K+ concentration ([K+]o) from 6 to 12 mM. In aortic rings, the Na+ ionophore monensin evoked EDR, and this EDR was inhibited by the Na+/Ca2+ exchanger (NCX; reverse mode) inhibitor KB-R7943. Monensin-induced Na+ loading or extracellular Na+ depletion (Na+ replaced by Li+) increased [Ca2+]i in MAECs, and this increase was inhibited by KB-R7943. Na+-K+ pump activation inhibited EDR and [Ca2+]i increase (K+-induced inhibition of EDR and [Ca2+]i increase). The Na+-K+ pump inhibitor ouabain inhibited K+-induced inhibition of EDR. Monensin (>0.1 microM) and the NCX (forward and reverse mode) inhibitors 2'4'-dichlorobenzamil (>10 microM) or Ni2+ (>100 microM) inhibited K+-induced inhibition of EDR and [Ca2+]i increase. KB-R7943 did not inhibit K+-induced inhibition at up to 10 microM but did at 30 microM. In current-clamped MAECs, an increase in [K+]o from 6 to 12 mM depolarized the membrane potential, which was inhibited by ouabain, Ni2+, or KB-R7943. In aortic rings, the concentration of cGMP was significantly increased by acetylcholine and decreased on increasing [K+]o from 6 to 12 mM. This decrease in cGMP was significantly inhibited by pretreating with ouabain (100 microM), Ni2+ (300 microM), or KB-R7943 (30 microM). These results suggest that activation of the forward mode of NCX after Na+-K+ pump activation inhibits Ca2+ mobilization in endothelial cells, thereby modulating vasomotor tone.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1152/ajpheart.00908.2004 | DOI Listing |
Biomacromolecules
November 2022
Department of Biotechnology, The Catholic University of Korea, 43 Jibong-ro, Wonmi-gu, Bucheon-si, Gyeonggi-do14662, Republic of Korea.
Here, we describe an intracellular pH-regulating nanoparticle (IPRN), coencapsulated with chemosensitizers and anticancer agents for effective and safe cancer treatment. IPRN contains a tubulysin derivative (TUB), a hydrophobic anticancer drug, and pantoprazole (PTZ), a hydrophilic proton-pump inhibitor. IPRN with a size of 62 nm has an anionic surface charge and is stable for at least two weeks under storage conditions, though PTZ and TUB encapsulated in IPRN showed different drug release patterns.
View Article and Find Full Text PDFPain Physician
September 2022
Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, Republic of Korea; Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea.
Background: Although nefopam has been reported to have opioid-sparing and analgesic effects in postsurgical patients, its effectiveness in video-assisted thoracoscopic surgery (VATS) is unknown.
Objectives: This study aimed to investigate the opioid-sparing and analgesic effects of perioperative nefopam infusion for lung resection.
Study Design: Double-blinded randomized controlled trial.
J Card Surg
May 2022
Department of Thoracic and Cardiovascular Surgery, Chonnam National University Hospital, Chonnam National University School of Medicine, Gwangju, Korea.
Background: Visceral artery aneurysm is a very rare disease, but it is clinically important because of the high risk of rupture involved. These ruptures must be differentiated from those that occur during hospitalization after extra-abdominal surgery.
Methods: During hospitalization after off-pump coronary artery bypass grafting, a 77-year-old woman developed hypovolemic symptoms and had decreased hemoglobin.
J Cardiothorac Surg
November 2016
Department of Thoracic and Cardiovascular Surgery, Chonnam National University Hospital, Chonnam National University School of Medicine, 42 Jebong-ro, Dong-gu, Gwangju, 501-757, South Korea.
Background: Coronary artery bypass grafting (CABG) with a composite Y-graft made of the left internal thoracic artery (LITA) and another arterial graft has a risk for hypoperfusion. Changes over time in the diameter of the LITA anastomosed to the left anterior descending coronary artery (LAD) are not known.
Methods: Data were collected for 71 patients who had undergone coronary angiography (CAG) immediately and at 1 year following off-pump CABG with a composite Y-graft made of the LITA and either the radial artery or the right gastroepiploic artery.
J Biosci Bioeng
May 2016
Interdisciplinary Program for Bioengineering, Seoul National University, Seoul 151-742, Republic of Korea. Electronic address:
Unlabelled: This study describes the development and experimental verification of a modified harvest system to enhance Factor VIII (FVIII) yield in an alternating tangential flow (ATF) perfusion culture. The main innovation of the modified harvest system is the use of check and pinch valves, eliminating the need of a peristaltic pump for harvest. The system was applied to perfusion cultures of Chinese hamster ovary cells, which co-express both recombinant human FVIII (rhFVIII) and von Willebrand factor (vWF).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!