Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (dioxins and furans) are persistent, bioaccumulative and highly toxic chemical constituents that appear in the environment at very low and difficult to measure levels. Although dioxins and furans are widely recognized as toxic contaminants needing regulation, their temporal and spatial concentration profiles and the factors impacting their partitioning and congener distribution are only moderately understood. This paper presents the results from one of the most extensive ambient air dioxin and furan sampling efforts conducted in a geographic area to date. The data consist of monthly ambient concentrations of 17 of the most toxic congeners of dioxins and furans collected at five locations in Houston, Texas over a calendar year. The results showed a total annual mean dioxin and furan congener concentration of 1047 fg/m3 and an annual mean summation operatorI-TEQ concentration of 15 fg I-TEQ/m3 (16 fg WHO-TEQ/m3). These results, when compared with proximate data from the USEPA National Dioxin Ambient Monitoring Network (NDAMN), revealed significant (at the P0.05 level) differences between Houston and the NDAMN sites, suggesting the existence of local dioxin sources. A temporal analysis of the data showed that the congener concentration distribution varies over time, depending on the level of chlorination, type of congener, and temperature. The results also suggested that the fluctuations of congener concentrations and I-TEQ concentrations are closely correlated with minimum relative humidity, mean temperature, and mean NOx concentration.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chemosphere.2004.12.057 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!