A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Hepatic hemorrhage caused by percutaneous tumor ablation: radiofrequency ablation versus cryoablation in a porcine model. | LitMetric

Purpose: To determine the extent of hepatic hemorrhage caused by percutaneous cryoablation performed with a small-diameter cryoablation probe compared with that caused by percutaneous radiofrequency (RF) ablation in a porcine model.

Materials And Methods: The study was pre-approved by the institutional research animal care and use committee, and husbandry and experiments complied with National Institutes of Health standards for care and use of laboratory animals. Percutaneous hepatic ablation was performed in 18 domestic pigs (mean weight, 45 kg) by using a 17-gauge (1.5-mm-diameter) RF electrode (n = 6), a cluster of three RF electrodes (n = 6), or a 13-gauge (2.4 mm-diameter) cryoprobe (n = 6). Ablation was performed in four sites per liver. Total blood loss, minimum lesion diameter, maximum lesion diameter, and lesion volume were determined for each group and compared by using analysis of variance.

Results: Mean blood loss was 11.11 mL +/- 11.47 (standard deviation), 105.29 mL +/- 175.58, and 28.06 mL +/- 30.97 with the single RF electrode, RF electrode cluster, and cryoablation probe, respectively. Mean minimum and maximum lesion diameters were largest with the RF electrode cluster (2.40 and 3.98 cm, respectively), followed by the cryoablation probe (2.38 and 3.94 cm) and single RF electrode (1.49 and 2.63 cm). Mean minimum and maximum lesion diameters were significantly different between the single RF electrode and the RF electrode cluster, as well as between the single RF electrode and the cryoablation probe (P < .001). Mean lesion volume was largest for the RF electrode cluster (24.03 cm3), followed by those for the cryoablation probe (17.46 cm3) and single RF electrode (9.05 cm3) (single RF electrode vs cryoablation probe, P < .05). Lesion volumes were not significantly different with the RF electrode cluster versus the single RF electrode (P = .052) or with the RF electrode cluster versus the cryoablation probe (P = .381).

Conclusion: Mean blood loss from percutaneous cryoablation in this model was between that for RF ablation with the single electrode and that for RF ablation with the electrode cluster.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2361040533DOI Listing

Publication Analysis

Top Keywords

electrode cluster
32
single electrode
32
cryoablation probe
28
electrode
16
caused percutaneous
12
blood loss
12
maximum lesion
12
cryoablation
10
hepatic hemorrhage
8
hemorrhage caused
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!