The aim of this study is to assess safety, reliability, ease of use and usefulness of filter protection devices during angioplasty and stenting of stenotic lesions of the cervical carotid bifurcation. Over a period of 42 months, 53 patients harboring a cervical carotid bifurcation stenotic lesion were treated, by angioplasty and/or stenting using filter protection devices of different kinds. The stenosis was atherosclerotic in 48 cases, post-surgical in four and post-radiation in one case. In all cases, the treatment was successful, with good restoration of the luminal diameter. There were three major strokes (5.6%) and one minor stroke (1.9%). Two of these (one major, one minor) occurred a few hours after the stenting procedure and both seemed by all evidence due to a hemorrhagic hyperperfusion syndrome. One hemiparesis and dysphasia occurred two days after the procedure, secondary to subacute thrombosis with occlusion of the stent. One patient complained of three episodes of decrease in visual acuity of the eye ipsilateral to the stenting in the two weeks following treatment. In conclusion, in our experience, use of the devices adds only few minutes to the procedure time; direct lesions of the arterial wall, such as dissections or intraluminal thrombi, related to the use of filters were never observed, and spasm of the distal I.C.A. also proved rapidly regressive. The content of all filters, if any, was histologically examined, but plaque material was found only in one case, probably owing to our primary stenting technique without use of pre-dilation. The major technical drawback is in-filter coagulation, which occurred in 16 cases, occluding the membrane of the filter and thus slowing or blocking intracranial flow. Such an event can be counteracted by a more aggressive anti-coagulation protocol, which could, however, be responsible for the two complications with hemorrhagic brain infarction. Furthermore, we observed two other major neurological events, which bring the incidence of neurological complications in this series as high as 7.5%. Therefore, it is our opinion that safety of filters is not yet proven, and consequently great care must be taken in their use.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0150-9861(05)83125-6 | DOI Listing |
Neuroradiol J
January 2025
Department of Neuroradiology, Teaching Hospital of Paracelsius Medical University (PMU), Hospital of Bolzano (SABES-ASDAA), Bolzano-Bozen, Italy.
Occlusion of the distal internal carotid artery can simulate a proximal occlusion of its cervical tract on CT angiography in patients with acute ischemic stroke, that is, pseudo-occlusion. As true and false carotid occlusions can present similarly on non-invasive imaging in patients undergoing endovascular treatment for stroke, our study aimed to evaluate clinical and technical differences of these conditions and the possible consequences of a misdiagnosis. We retrospectively reviewed consecutive patients who underwent mechanical thrombectomy for acute ischemic stroke at a single center between July 2015 and May 2022 and included patients with absent opacification of the cervical carotid artery on CT-angiography.
View Article and Find Full Text PDFBioengineering (Basel)
January 2025
School of Biomedical Sciences, Faculty of Medicine, The University of Queensland, Brisbane, QLD 4072, Australia.
The haptic fidelity of biomimetic materials used in the design of procedural task trainers is of growing interest to the medical community. Shore hardness has been proposed as a method for assessing tissue biomechanics and replicating the results as a way to increase the fidelity of biomimetics to tissues. However, there is limited research on the reliability of human tissue measurements using Shore scales.
View Article and Find Full Text PDFSurg Radiol Anat
January 2025
Department of Neurosurgery, Nakamura Memorial Hospital, South 1, West 14, Chuo-ku, Sapporo, Hokkaido, 060-8570, Japan.
Purpose: Anatomical variations in the anterior choroidal artery (AChA) and/or the posterior cerebral artery (PCA) are rare. Hyperplastic AChA is an anatomical variant supplying both the AChA area and the PCA area. In accessory PCA, a hyperplastic AChA supplies part of the PCA territory.
View Article and Find Full Text PDFCureus
December 2024
Department of Pediatrics, Japanese Red Cross Wakayama Medical Center, Wakayama, JPN.
Acute ischemic stroke, a medical emergency caused by reduced cerebral blood flow, results in brain cell damage. While commonly associated with older individuals, strokes can also occur in young and middle-aged adults, posing significant socio-economic and health challenges due to the long-term impact of the condition. This poses significant socio-economic and health challenges because stroke is a leading cause of disability and mortality.
View Article and Find Full Text PDFQuant Imaging Med Surg
January 2025
Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Background: The scanning trigger threshold affects image quality. The aim of this study was to investigate the effect of different scanning trigger thresholds on brain computed tomography angiography (CTA) image quality.
Methods: In this prospective study, 80 patients undergoing brain CTA examinations with dual-layer CT (DLCT) were randomly divided into group A and group B, with 40 patients in each group.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!