Thousands of adult cardiac failure patients may benefit from the availability of an effective, long-term ventricular assist device (VAD). We have developed a fully implantable, axial flow VAD (LEV-VAD) with a magnetically levitated impeller as a viable option for these patients. This pump's streamlined and unobstructed blood flow path provides its unique design and facilitates continuous washing of all surfaces contacting blood. One internal fluid contacting region, the diffuser, is extremely important to the pump's ability to produce adequate pressure but is challenging to manufacture, depending on the complex blade geometries. This study examines the influence of the diffuser on the overall LEV-VAD performance. A combination of theoretical analyses, computational fluid (CFD) simulations, and experimental testing was performed for three different diffuser models: six-bladed, three-bladed, and no-blade configuration. The diffuser configurations were computationally and experimentally investigated for flow rates of 2-10 L/min at rotational speeds of 5000-8000 rpm. For these operating conditions, CFD simulations predicted the LEV-VAD to deliver physiologic pressures with hydraulic efficiencies of 15-32%. These numerical performance results generally agreed within 10% of the experimental measurements over the entire range of rotational speeds tested. Maximum scalar stress levels were estimated to be 450 Pa for 6 L/min at 8000 rpm along the blade tip surface of the impeller. Streakline analysis demonstrated maximum fluid residence times of 200 ms with a majority of particles exiting the pump in 80 ms. Axial fluid forces remained well within counter force generation capabilities of the magnetic suspension design. The no-bladed configuration generated an unacceptable hydraulic performance. The six-diffuser-blade model produced a flow rate of 6 L/min against 100 mm Hg for 6000 rpm rotational speed, while the three-diffuser-blade model produced the same flow rate and pressure rise for a rotational speed of 6500 rpm. The three-bladed diffuser configuration was selected over the six-bladed, requiring only an incremental adjustment in revolution per minute to compensate for and ease manufacturing constraints. The acceptable results of the computational simulations and experimental testing encourage final prototype manufacturing for acute and chronic animal studies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1525-1594.2005.29095.x | DOI Listing |
Front Med (Lausanne)
December 2024
Chongqing Key Laboratory of Prevention and Treatment on Major Blinding Diseases, Chongqing Eye Institute, Chongqing Branch (Municipality Division) of National Clinical Research Center for Ocular Diseases, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
BMC Surg
January 2025
Chongqing Nanping Aier Ophthalmology, 249 Nancheng Avenue, Nanan District, Chongqing, P. R. China.
Purpose: This study aims to examine the correlation between specific clinical parameters, such as axial eye length, and the onset of ocular hypertension "OH" following the use of silicone oil filling in patients with high myopia.
Method: In this retrospective analysis, we reviewed 214 eyes from 432 patients diagnosed with severe myopia, all of whom underwent vitrectomy and were treated with silicone oil filling. The study aimed to document the incidence and timing of postoperative ocular hypertension "OH" while assessing various factors, including demographic details, medical history, additional surgical interventions, and findings from supplementary examinations (such as axial length, silicone oil emulsification, and anterior chamber penetration).
ACS Omega
December 2024
School of Minerals Processing and Bioengineering, Central South University, Changsha 410083, China.
As natural resources continue to be exploited, dense medium cyclones (DMCs) are increasingly utilized for the preconcentration of low-grade ores to meet the demands for higher feed grade, increased processing capacity, and reduced energy consumption. However, determining the optimal fineness of ferrosilicon remains ambiguous for different types of ores and is often described as more of an art than a science. This paper investigates the subtle effects of ferrosilicon fineness on flow field characteristics, medium classification, and the ore separation process using a validated numerical approach, which integrates a two-fluid model, a turbulence dispersion model, and a discrete phase model.
View Article and Find Full Text PDFComput Biol Med
December 2024
Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology Madras, Chennai, 600036, Tamil Nadu, India. Electronic address:
Background And Objective: Cerebral aneurysms occur as balloon-like outpouchings in an artery, which commonly develop at the weak curved regions and bifurcations. When aneurysms are detected, understanding the risk of rupture is of immense clinical value for better patient management. Towards this, Fluid-Structure Interaction (FSI) studies can improve our understanding of the mechanics behind aneurysm initiation, progression, and rupture.
View Article and Find Full Text PDFBiomimetics (Basel)
December 2024
Department of Aeronautics and Astronautics, National Cheng Kung University, Tainan 701, Taiwan.
In this study, a fish scale structure with low viscous drag was proposed and applied to the suction surface of a compressor cascade to reduce total pressure loss and suppress corner separation, a key source of compressor inefficiency. By using CFD simulations, the biomimetic structure was identified and integrated into the cascade design. To evaluate its effects, we analyzed secondary flow structures using 2D projected streamlines, axial velocity density (AVD), and vortex visualization techniques.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!