A magnetically levitated (MagLev) centrifugal blood pump (CBP) with a disposable pump head has been designed to realize a safe, easy-to-handle, reliable, and low-cost extracorporeal blood pump system. It consisted of a radial magnetic-coupled driver with a magnetic bearing having a two-degree freedom control and a disposable pump head unit with a priming volume of 24 mL. The easy on-off disposable pump head unit was made into a three-piece system consisting of the top and bottom housings, and the impeller-rotor assembly. The size and weight of the disposable pump unit were 75 mm x 45 mm and 100 g, respectively. Because the structure of the pump head unit is easily attachable and removable, the gap between the electromagnets of the stator and the target material in the rotor increased to 1.8 mm in comparison to the original integrated bearing system of 1.0 mm. The pump performance, power requirements, and controllability of the magnetic bearing revealed that from 1400 to 2400 rpm, the pump performance remained fairly unchanged. The amplitudes of the X- and Y-axis rotor oscillation increased to +/- 24 microm. The axial displacement of the rotor, 0.4 mm, toward the top housing was also observed at the pump rpm between 1400 and 2400. The axial and rotational stiffness of the bearing were 15.9 N/mm and 4.4 Nm/rad, respectively. The MagLev power was within 0.7 Watts. This study demonstrated the feasibility of a disposable, magnetically suspended CBP as the safe, reliable, easy-to-handle, low-cost extracorporeal circulation support device.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1525-1594.2005.29087.xDOI Listing

Publication Analysis

Top Keywords

disposable pump
16
pump head
16
blood pump
12
head unit
12
pump
11
disposable magnetically
8
magnetically levitated
8
centrifugal blood
8
low-cost extracorporeal
8
magnetic bearing
8

Similar Publications

A comparison of routine [Ga]Ga-PSMA-11 preparation using Locametz and Illuccix kits.

EJNMMI Radiopharm Chem

December 2024

Department of Medicinal Chemistry, College of Pharmacy, University of Michigan, Ann Arbor, MI, 48109, USA.

Background: Approval of Locametz and Illuccix kits for the manufacture of [Ga]Ga-PSMA-11 (gallium Ga68 gozetotide), a PET imaging agent for prostate cancer, as well as the corresponding therapeutic ([Lu]Lu-PSMA-617 Pluvicto), has led to a rapid increase in demand for [Ga]Ga-PSMA-11 PET imaging. Radiopharmaceutical manufacturers, using Ge/Ga generators, may decide to adopt Locametz and/or Illuccix kits, which requires a comparison to select the most suitable kit for day-to-day use. The objective of this article is to compare both kits and provide guidance for selecting one for routine use, as well as evaluate labeling consistency of both kits during routine production.

View Article and Find Full Text PDF

There have been few recent innovations since the introduction of cardioplegia more than 50 years ago. Surprisingly, cardioplegia as one of the most essential steps in terms of heart muscle protection during a surgical procedure requiring cardiac arrest has never been really standardized. As a consequence, a considerable variety of cardioplegic solutions and applications have developed: cold versus warm, crystalloid versus blood cardioplegia, antegrade versus retrograde or both, as well as different time schedules for repeated administration.

View Article and Find Full Text PDF

OpenPrep: Sensor Event-driven Open Column Chromatographic Sample Preparation System.

Anal Chem

November 2024

Advanced Fuel Cycle Technology Division, Korea Atomic Energy Research Institute, 111 Daedeok-daero 989, Yuseong-gu, Daejeon 34057, Republic of Korea.

We propose a sensor event-driven, open-column chromatographic sample preparation system─OpenPrep. This system replaces the problematic flow selector valve with a noncontact built-in sensor, eliminating carryover and clogging issues, which are commonly encountered in pump-driven chromatographic systems. The innovative valveless column-flow design, combined with a compact gantry dispenser and motion stage-based fraction collector, reduces the sample flow path to a disposable component with a postcolumn dead volume of only 0.

View Article and Find Full Text PDF

A Comparison of Pumping Infusion-Induced Contamination With Different Syringe Types.

J Infus Nurs

November 2024

Author Affiliations: Department of Emergency and Critical Care Medicine, Nippon Medical School Musashikosugi Hospital, Nakahara-ku, Kawasaki, Japan.

Health care providers use several types of syringes in their daily routine to provide or safely deliver therapeutic agents to patients. Pump infusion with a syringe (PIS) are used for the rapid delivery of large amounts of fluid or blood to patients in critical conditions, such as hypovolemic shock. Patients often experience bacterial infections, such as catheter-related bloodstream infections, specifically when they are in critical condition in the intensive care unit (ICU) after surgery or undergoing resuscitation in an emergency department.

View Article and Find Full Text PDF

Background: Recent studies have underscored the potential of innovative administration methods to mitigate the capacity burden on healthcare systems, without compromising the quality of care. This study assessed and compared the resource utilization and associated costs of two distinct administration modes of immune checkpoint inhibitors: the innovative elastomeric pump and conventional intravenous infusion. This comparison can inform sustainable healthcare practices and healthcare decision-making to optimize treatment efficiency in an era of escalating healthcare demands.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!