Unlabelled: Urban PM2.5 (particulate matter with aerodynamic diameter smaller than 2.5 microm) is associated with excess mortality and other health effects. Stationary sources are regulated and considerable effort is being put into developing low-pollution vehicles and environment-friendly transportation systems. While waiting for technological breakthroughs in emission controls, the current work assesses the exposure reductions achievable by a complementary means: efficient filtration of supply air in buildings. For this purpose infiltration factors for buildings of different ages are quantified using Exposures of Adult Urban Populations in Europe Study (EXPOLIS) measurements of indoor and outdoor concentrations in a population-based probability sample of residential and occupational buildings in Helsinki, Finland. These are entered as inputs into an evaluated simulation model to compare exposures in the current scenario with an alternative scenario, where the distribution of ambient PM2.5 infiltration factors in all residential and occupational buildings are assumed to be similar to the subset of existing occupational buildings using supply air filters. In the alternative scenario exposures to ambient PM2.5 were reduced by 27%. Compared with source controls, a significant additional benefit is that infiltration affects particles from all outdoor sources. The large fraction of time spent indoors makes the reduction larger than what probably can be achieved by local transport policies or other emission controls in the near future.

Practical Implications: It has been suggested that indoor concentrations of ambient particles and the associated health risks can be reduced by using mechanical ventilation systems with supply air filtering in buildings. The current work quantifies the effects of these concentration reductions on population exposures using population-based data from Helsinki and an exposure model. The estimated exposure reductions suggest that correctly defined building codes may reduce annual premature mortality by hundreds in Finland and by tens of thousands in the developed world altogether.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1600-0668.2005.00365.xDOI Listing

Publication Analysis

Top Keywords

supply air
12
occupational buildings
12
urban pm25
8
ventilation systems
8
emission controls
8
current work
8
exposure reductions
8
infiltration factors
8
residential occupational
8
alternative scenario
8

Similar Publications

Background: Bacteria in physiological environments can generate mineralizing biofilms, which are associated with diseases like periodontitis or kidney stones. Modelling complex environments presents a challenge for the study of mineralization in biofilms. Here, we developed an experimental setup which could be applied to study the fundamental principles behind biofilm mineralization on rigid substrates, using a model organism and in a tailored bioreactor that mimics a humid environment.

View Article and Find Full Text PDF

Biofiltration for odor mitigation in water resource recovery facilities.

Sci Total Environ

January 2025

Department of Civil Engineering, City College of New York, New York, NY 10031, United States.

Odor emissions, primarily from anthropogenic activities like waste treatment and industrial processes, pose significant challenges in urban areas, particularly near water resource recovery facilities. While these emissions are generally not toxic, they can adversely affect community wellbeing and investment, prompting stricter regulations in some regions. For example, New York State's hydrogen sulfide guidelines are more stringent than federal standards.

View Article and Find Full Text PDF

Globally, domestic refrigerators account for over 13% of the total energy consumption in residential buildings. The brazed plate water-cooled condenser (BPWCC) is compact in size and an attractive option to reduce the energy consumption of refrigerators using domestic water tanks. This study evaluated the performance of a household refrigerator with a secondary refrigerant calorimeter and BPWCC, using an appropriate experimental setup.

View Article and Find Full Text PDF

Periprosthetic joint infections occur in 1-2% of all patients undergoing prosthetic joint surgeries. Although strong efforts have been made to reduce infection rates, conventional therapies like one- or two-stage revisions have failed to lower the infection rates. Cold atmospheric plasma (CAP) has shown promising results in reducing bacterial loads on surfaces.

View Article and Find Full Text PDF

Reusable Biosensor for Easy RNA Detection from Unfiltered Saliva.

Sensors (Basel)

January 2025

Department of Clinical and Molecular Biochemistry, Pomeranian Medical University in Szczecin, 72 Powstańców Wlkp. Al., 70-111 Szczecin, Poland.

Biosensors are transforming point-of-care diagnostics by simplifying the detection process and enabling rapid, accurate testing. This study introduces a novel, reusable biosensor designed for direct viral RNA detection from unfiltered saliva, targeting SARS-CoV-2. Unlike conventional methods requiring filtration, our biosensor leverages a unique electrode design that prevents interference from saliva debris, allowing precise measurements.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!