The purpose of the study was; (i) to determine whether 123I-MIBG scintigraphy is sensitive for detection of amiodarone induced pulmonary toxicity (AIPT) and (ii) to compare it with 99mTc-DTPA radioaerosol. Twelve white New Zealand rabbit with initial mean body weight 4.24 +/- 0.47 g were divided into two groups. AIPT group (n = 7) was administered amiodarone (20 mg/kg BW). The control group (n = 5) received the same amount of 0.9% saline. All animals underwent 123I-MIBG and 99mTc-DTPA radioaerosol scintigraphy at the end of the treatment period. 123I-MIBG static thorax images were obtained during 10 minutes at 15 minutes and 3-hours after intravenous injection of the radiopharmaceutical. Lung to heart ratios (LHR) and lung to mediastinum ratios (LMR), and retention index (LRI) of 123I-MIBG were determined. Two days after 123I-MIBG scintigraphy, 99mTc-DTPA radioaerosol scintigraphy was performed, and clearance from the lungs was measured for 10 min (1 min/frame) following termination of inhalation. 123I-MIBG lung retention index (LRI) was significantly higher in the AIPT group than the control (61 +/- 4.6 vs. 40 +/- 4.5, p = 0.01). Early LHR and LMR were significantly lower in the AIPT group than in the control group (p = 0.04, p = 0.01, respectively), whereas those of late LHR and LMR were not significantly different. T1/2 values of DTPA clearance were significantly increased in AIPT group according to the control group (55 +/- 7.2 vs. 86.6 +/- 18.5, p = 0.02). 123I-MIBG scintigraphy is a valuable tool for detecting AIPT in a rabbit model. Additionally, 99mTc-DTPA radioaerosol scintigraphy is an excellent comprehensive investigational tool for detecting AIPT with the added advantage of lower cost.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/BF02984608 | DOI Listing |
Appl Radiat Isot
January 2025
Department of Chemistry, Universitas Indonesia, Depok, 16424, Indonesia.
To investigate the potential of activated carbon from palm kernel shell waste for Tc-radiolabeled nanocarbon aerosol, a new production technology for carbon-based Tc-radioaerosol from such a waste was developed. Treated-palm shell charcoal (t-PSC) was prepared by hydrothermal method to increase the surface area, followed by Tc radiolabelling optimization. The optimal Tc radiolabeling conditions resulted in an adsorption capacity of 21.
View Article and Find Full Text PDFJ Aerosol Med Pulm Drug Deliv
February 2023
Department of Medical Physics, University Hospital Southampton NHS Foundation Trust, National Institute of Health Research Biomedical Research Centre, Southampton, United Kingdom.
Imaging of radiolabeled aerosols provides useful data on both the initial site of deposition and its subsequent transport by mucociliary clearance and epithelial permeability. Single Photon Emission Computed Tomography (SPECT) uses a gamma camera with multiple rotating heads to produce three-dimensional (3D) images of inhaled radioaerosol labeled with technetium-99m. This enables total lung deposition and its 3D regional distribution to be quantified.
View Article and Find Full Text PDFClin Nucl Med
January 2023
Section of Nuclear Medicine, Department of Radiology, Penn State University Hospital, Hershey, PA.
Invented and first approved for clinical use in Australia 36 years ago, Technegas is the technology that enabled ventilation scintigraphy with 99m Tc-labeled carbon nanoparticles ( 99m Tc-CNP). The US Food and Drug Administration (FDA) has considered this technology for more than 30 years but only now is getting close to approving it. Meanwhile, more than 4.
View Article and Find Full Text PDFSemin Nucl Med
March 2022
Nuclear Medicine Department, Centre of Isotopes, Havana, Cuba.
Medical radiation accidents and unintended events may lead to accidental or unintended medical exposure of patients and exposure of staff or the public. Most unintended exposures in nuclear medicine will lead to a small increase in risk; nevertheless, these require investigation and a clinical and dosimetric assessment. Nuclear medicine staff are exposed to radiation emitted directly by radiopharmaceuticals and by patients after administration of radiopharmaceuticals.
View Article and Find Full Text PDFEur J Nucl Med Mol Imaging
July 2020
Jubilant DraxImage Inc., Kirkland, QC, Canada.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!