Purpose: To better understand the relationship between the amplitude of the pattern electroretinogram (PERG) and visual loss, measured with static automated perimetry.

Methods: Transient PERGs were recorded in 15 patients (31-77 years) and 16 normal individuals (26-65 years). An eye was considered to have glaucomatous damage only if there was an abnormal disc, an abnormal 24-2 Humphrey visual field result (pattern stand deviation, glaucoma hemifield test, and cluster) and an abnormal multifocal visual evoked potential. All the worse (more affected) eyes of the patients and six of the better eyes met these criteria. The N95 amplitude of the PERG was measured from the positive peak (P50) at approximately 50 ms to the trough at approximately 95 ms. The ratio of N95 to P50-the N95 amplitude divided by the P50 amplitude-was also measured.

Results: First, the PERG was within normal limits for 4 (26.7%) of the worse eyes. Overall, 6 (28.6%) of the 21 eyes that met the criteria for glaucomatous damage had normal PERGs on both PERG measures. Because the normal individuals were younger than the patients, an even larger number of normal PERGs might be expected with an age-appropriate control group. Second, the N95 amplitude was nonlinearly related to visual field sensitivity when sensitivity was plotted on a linear plot. Small field losses were associated with disproportionately large losses in PERG amplitude. Third, the PERG from both eyes of a patient were very similar, even when the visual fields suggested very different levels of damage.

Conclusions: These results are consistent with the view that very early damage can affect the PERG, even before the visual field shows a loss. At the same time, it is clear that patients with clear glaucomatous damage can have normal-appearing PERGs. An explanation is proposed to account for these findings.

Download full-text PDF

Source
http://dx.doi.org/10.1167/iovs.05-0238DOI Listing

Publication Analysis

Top Keywords

visual field
16
glaucomatous damage
12
n95 amplitude
12
pattern electroretinogram
8
perg visual
8
normal individuals
8
worse eyes
8
eyes met
8
met criteria
8
normal pergs
8

Similar Publications

Tachistoscopic studies have established a right field advantage for the perception of visually presented words, which has been interpreted as reflecting a left hemispheric specialization. However, it is not clear whether this is driven by the linguistic task of word processing, or also occurs when processing properties such as the style and regularity of text. We had 23 subjects perform a tachistoscopic study while they viewed five-letter words in either computer font or handwriting.

View Article and Find Full Text PDF

Quantifying tear exchange during rigid contact lens wear using corneoscleral profilometry: A proof of concept study.

Ophthalmic Physiol Opt

January 2025

Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.

Introduction: Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope. This manuscript introduces an alternative method using a corneoscleral profilometer, the Eye Surface Profiler (ESP), to quantify tear exchange during corneal and scleral rigid lens wear by assessing fluorescence intensity changes over time.

View Article and Find Full Text PDF

Background/ Aims: To analyze the longitudinal change in Bruch's membrane opening minimal rim width (BMO-MRW) and peripapillary retinal nerve fiber layer (pRNFL) thickness using optical coherence tomography (OCT) after implantation of a PRESERFLO® microshunt for surgical glaucoma management in adult glaucoma patients.

Methods: Retrospective data analysis of 59 eyes of 59 participants undergoing implantation of a PRESERFLO microshunt between 2019 and 2022 at a tertiary center for glaucoma management. Surgical management included primary temporary occlusion of the glaucoma shunt to prevent early hypotony.

View Article and Find Full Text PDF

COph100: A comprehensive fundus image registration dataset from infants constituting the "RIDIRP" database.

Sci Data

January 2025

Research Institute of Trustworthy Autonomous Systems and Department of Computer Science and Engineering, Southern University of Science and Technology, Shenzhen, China.

Retinal image registration is vital for diagnostic therapeutic applications within the field of ophthalmology. Existing public datasets, focusing on adult retinal pathologies with high-quality images, have limited number of image pairs and neglect clinical challenges. To address this gap, we introduce COph100, a novel and challenging dataset known as the Comprehensive Ophthalmology Retinal Image Registration dataset for infants with a wide range of image quality issues constituting the public "RIDIRP" database.

View Article and Find Full Text PDF

Recent progress in CRISPR/Cas9 system for eye disorders.

Prog Mol Biol Transl Sci

January 2025

Graduate School of Biomedical Science and Engineering, Hanyang University, Seoul, South Korea; College of Medicine, Hanyang University, Seoul, South Korea. Electronic address:

Ocular disorders encompass a broad spectrum of phenotypic and clinical symptoms resulting from several genetic variants and environmental factors. The unique anatomy and physiology of the eye facilitate validation of cutting-edge gene editing treatments. Genome editing developments have allowed researchers to treat a variety of diseases, including ocular disorders.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!