A competitive lateral flow assay for detecting the major peanut allergen, Ara h1, has been developed. The detector reagents are Ara h1-tagged liposomes, and the capture reagents are anti-Ara h1 polyclonal antibodies. Two types of rabbit polyclonal antibodies were raised either against the entire Ara h1 molecules (anti-Ara h1 Ab) or against an immunodominant epitope on Ara h1 (anti-peptide Ab). All of them reacted specifically with Ara h1 in Western Blot against crude peanut proteins. Moreover, the anti-Ara h1 Ab was chosen for this assay development because of its highest immunoactivity to Ara h1-tagged liposomes in the lateral flow assay. The calculated limit of detection (LOD) of this assay is 0.45 microg mL(-1) of Ara h1 with a dynamic range between 0.1 and 10 microg mL(-1) of Ara h1 in buffer. Additionally, the visually determined detection range is from 1 to 10 microg mL(-1) of Ara h1 in buffer. Results using this assay can be obtained within 30 min without the need of sophisticated equipment or techniques; therefore, this lateral flow assay has the potential to be a cost-effective, fast, simple, and sensitive method for on-site screening of peanut allergens.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00216-005-3292-3 | DOI Listing |
Food Chem
January 2025
State Key Laboratory of Pulp and Paper Engineering, School of Light Industry and Engineering, South China University of Technology, Guangzhou 510640, China; Guangdong Provincial Key Laboratory of Plant Resources Biorefinery, Guangzhou 510006, China. Electronic address:
Lateral flow assays (LFAs) have found extensive applications in food safety and quality monitoring. Now, smartphone technology is redefining how tests are conducted at the point of use. At the same time, quick response (QR) codes enhance digital connectivity for information transmission, data collection, and response linkage.
View Article and Find Full Text PDFNano Lett
January 2025
Donostia International Physics Center (DIPC), E-20018 Donostia-San Sebastián, Spain.
Nanoporous graphene (NPG), laterally bonded carbon nanoribbons, is a promising platform for controlling coherent electron propagation in the nanoscale. However, for its successful device integration NPG should ideally be on a substrate that preserves or enhances its anisotropic transport properties. Here, using an atomistic tight-binding model combined with nonequilibrium Green's functions, we study NPG on graphene and show that their electronic coupling is modulated as a function of the interlayer twist angle.
View Article and Find Full Text PDFLab Chip
January 2025
NASCENT Engineering Research Center, The University of Texas at Austin, Austin, Texas 78758, USA.
Despite being a high-resolution separation technique, deterministic lateral displacement (DLD) technology is facing multiple challenges with regard to design, manufacture, and operation of pertinent devices. This work specifically aims at alleviating difficulties associated with design and manufacture of DLD chips. The process of design and production of computer-aided design (CAD) mask layout files that are typically required for computational modeling analysis, optimization, as well as for manufacturing DLD-based micro/nanofluidic chips is complex, time-consuming, and often necessitates a high level of expertise in the field.
View Article and Find Full Text PDFZhonghua Xin Xue Guan Bing Za Zhi
January 2025
Cardiology Department, Second Affiliated Hospital of Dalian Medical University, Dalian116021, China.
To assess the effectiveness of transcatheter aortic valve replacement (TAVR) on electrocardiographic remodeling in patients with severe aortic stenosis (AS), and identify its influencing factors. A cohort study was conducted on patients with a confirmed diagnosis of severe AS who successfully underwent TAVR at the Second Affiliated Hospital of Dalian Medical University between June 2018 and March 2023. Data, including standard 15-lead electrocardiograms and echocardiograms, were collected before the operation, 1 week after the operation, and 3 months after the operation.
View Article and Find Full Text PDFBMC Glob Public Health
January 2025
UK Health Security Agency, London, UK.
Background: The UK's National Health Service Test and Trace (NHSTT) program aimed to provide the most effective and accessible SARS-CoV-2 testing approach possible. Early user feedback indicated that there were accessibility issues associated with throat swabbing. We report the results of service evaluations performed by NHSTT to assess the effectiveness and user acceptance of swabbing approaches, as well as qualitative findings of user experiences from research reports, surveys, and incident reports.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!