Background: Loss of left ventricular capture in patients with cardiac resynchronization devices may account for worsening heart failure and can be difficult to diagnose without a programmer.

Objective: To determine whether distinct morphologic changes on the surface electrocardiogram indicate loss of left ventricular capture.

Design: After analysis of the R-S spike ratio in the 12-lead electrocardiogram during right ventricular and biventricular pacing in 10 patients, an algorithm to detect loss of left ventricular capture was developed.

Setting: University hospital.

Patients: 54 patients with a cardiac resynchronization device and underlying left bundle-branch block.

Measurements: Leads V1 and I of a 12-lead electrocardiogram were assessed after biventricular pacing was confirmed and after the device was programmed to right ventricular pacing only (simulating loss of left ventricular capture).

Results: The sensitivity of the algorithm to correctly identify loss of left ventricular capture was 94% (95% CI, 88.2% to 97.7%), and the specificity was 93% (CI, 86.3% to 95.8%). The likelihood ratio of a positive test result was 12.8 (CI, 6.443 to 23.310), and the likelihood ratio of a negative test result was 0.06 (CI, 0.024 to 0.137).

Limitations: The algorithm was tested in patients in whom the right ventricular electrode was placed in the apex of the right ventricle only.

Conclusion: Presence of biventricular capture--the prerequisite for successful cardiac resynchronization therapy--and loss of left ventricular capture can be accurately detected by an algorithm based on analysis of the R-S ratio on leads V1 and I of the surface electrocardiogram.

Download full-text PDF

Source
http://dx.doi.org/10.7326/0003-4819-142-12_part_1-200506210-00006DOI Listing

Publication Analysis

Top Keywords

loss left
28
left ventricular
28
ventricular capture
20
cardiac resynchronization
16
ventricular
10
algorithm detect
8
detect loss
8
left
8
patients cardiac
8
surface electrocardiogram
8

Similar Publications

Patent ductus arteriosus (PDA) stenting is a vital intervention for neonates with ductal-dependent blood flow, offering an attractive alternative to surgical shunt placement. Despite its benefits, the procedure poses risks such as ductal spasm, branch pulmonary artery compromise, and pseudoaneurysm formation. This report presents two complex neonatal cases with distinct outcomes.

View Article and Find Full Text PDF

Glioblastoma multiforme (GBM) is a World Health Organisation (WHO) grade IV glioma originating from astrocytes. It is the most common malignant primary tumour of the brain and central nervous system (CNS) and is associated with fast progression and violent local spread, with a median overall survival of approximately 15 months after diagnosis. Due to its late and varied presentation, it is often diagnosed only after it has grown considerably.

View Article and Find Full Text PDF

First full intracorporeal robotic cystectomy and neobladder in a renal transplant recipient.

J Surg Case Rep

January 2025

UNICAEN, Urology and Transplantation Department, Normandie University, CHU de Caen, Avenue de la Côte de Nacre, Caen 14000, France.

The literature regarding robotic-assisted radical cystectomy in kidney transplant recipients is limited. We present the first reported case of robotic-assisted radical cystectomy with a full intracorporeal orthotopic neobladder in a kidney transplant recipient. A 36-year-old man was diagnosed with muscle-invasive urothelial carcinoma 12 years after kidney transplantation.

View Article and Find Full Text PDF

Evaluating the Safety and Usability of an Over-the-Counter Medical Device for Adults With Mild to Moderate Hearing Loss: Formative and Summative Usability Testing.

JMIR Hum Factors

January 2025

Center for Research and Innovation in Systems Safety, Department of Anesthesiology, Vanderbilt University Medical Center, 2525 West End Avenue, Suite 800, Nashville, TN, 37203, United States, 16153431528.

Background: Only 15% of the nearly 30 million Americans with hearing loss use hearing aids, partly due to high cost, stigma, and limited access to professional hearing care. Hearing impairment in adults can lead to social isolation and depression and is associated with an increased risk of falls. Given the persistent barriers to hearing aid use, the Food and Drug Administration issued a final rule to allow over-the-counter hearing aids to be sold directly to adult consumers with perceived mild to moderate hearing loss at pharmacies, stores, and online retailers without seeing a physician or licensed hearing health care professional.

View Article and Find Full Text PDF

Background: Meniere's disease arises when an abnormal fluid accumulation results in heightened pressure within the inner ear or labyrinth. Its symptoms encompass vertigo, tinnitus, hearing loss, and a sensation of fullness in the ear. Various triggers for Meniere's disease are known, from smoking and alcohol consumption to recent viral illnesses, allergies, and anxiety.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!