A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Design of monolimb using finite element modelling and statistics-based Taguchi method. | LitMetric

Design of monolimb using finite element modelling and statistics-based Taguchi method.

Clin Biomech (Bristol)

Jockey Club Rehabilitation Engineering Centre, The Hong Kong Polytechnic University, Hong Kong, PR China.

Published: August 2005

Background: Monolimb is a transtibial prosthesis having the socket and shank molded into one piece of thermoplastic material. If properly designed, the shank of a monolimb can have a controlled deflection during walking which simulates the ankle joint motions to some extent. However, there is no clear guidance for the design of monolimb considering the dilemma between shank flexibility and structural integrity.

Methods: Finite element analysis was used to simulate structural tests based on ISO10328 on monolimbs of different configurations. Statistics-based Taguchi method was employed to identify the significance of each design factor in controlling the deformation and stress within monolimbs. The design factors considered were the thickness of the thermoplastics, anteroposterior and medialateral dimensions of the elliptical shank, and depth of the posterior seam line. By progressively fine-tuning the design factors, the monolimb configuration was optimized giving offering appropriate flexibilities of the shank and would not structurally fail in normal uses. Experimental structural test was used to validate the finite element model.

Findings: Anteroposterior dimension of the shank was shown to be the most important design factor determining the peak von Mises stress values, deformation and dorsiflexion angles of monolimbs. Depth of seam line appears much less important than the other three factors. A monolimb fulfilling the design requirements was suggested. Experimental test results reasonably matched with the finite element results.

Interpretation: Finite element analysis and Taguchi method was shown to be an effective method in optimizing the structural design of prostheses. Further prosthetic design can be facilitated based on the degree of importance of the design factors on the structural behavior of the prosthesis. Gait analysis of amputees using the suggested monolimb design is needed in the future.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiomech.2005.03.015DOI Listing

Publication Analysis

Top Keywords

finite element
20
taguchi method
12
design factors
12
design
11
design monolimb
8
statistics-based taguchi
8
element analysis
8
design factor
8
factors monolimb
8
monolimb
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!