This study compared the results in 60 consecutive patients with severe rheumatic mitral stenosis, who underwent percutaneous double-balloon mitral valvuloplasty by means of a combination of 20 mm + 20 mm diameter balloon catheters (group A), with a similar group of 60 consecutive patients who underwent single (Inoue) balloon mitral valvuloplasty (group B). After balloon mitral valvuloplasty the hemodynamic measurements showed significant improvement in both groups: in groups A and B, respectively, mitral valve area calculated with the Gorlin formula increased from 0.9 +/- 0.2 to 2.1 +/- 0.5 cm2 (p less than 0.001) and from 0.8 +/- 0.2 to 1.9 +/- 0.4 cm2 (p less than 0.001). There was a significant improvement in cardiac functional status in both groups. There was no significant difference between the groups with regard to clinical or hemodynamic improvement, technical failure rate, inadequacy of dilatation, or complications. However, the double-balloon technique was more complex and involved a longer screening time--group A, 40 +/- 12 minutes; group B, 21 +/- 10 minutes (p less than 0.001). In our institution the disposable supplies used for the Inoue balloon technique were 40% more expensive than those used for the double-balloon technique.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0002-8703(92)90813-bDOI Listing

Publication Analysis

Top Keywords

mitral valvuloplasty
16
balloon mitral
12
single inoue
8
consecutive patients
8
inoue balloon
8
+/- +/-
8
+/- cm2
8
cm2 0001
8
double-balloon technique
8
+/- minutes
8

Similar Publications

Interventricular septal dissection secondary to acute inferior myocardial infarction: case series and literature review.

J Cardiothorac Surg

January 2025

Echocardiography and Vascular Ultrasound Center, The First Affiliated Hospital, Zhejiang University School of Medicine, 79 Qingchun Road, Hangzhou, 310003, China.

Background: Interventricular septal dissection is a critical disease characterized by the separation of the intraventricular septum into two layers, forming an intermediate layer with a cystic cavity that communicates with the root of the aorta or ventricle. It has low morbidity and high mortality rates.

Case Presentation: Case 1: A 58-year-old male with a history of hypertension and smoking presented to a local hospital due to chest tightness and pain for 4 days.

View Article and Find Full Text PDF

Risk factors for long-term severe tricuspid regurgitation following mitral valve replacement: a retrospective study.

BMC Cardiovasc Disord

January 2025

Department of Cardiology, Xuzhou Central Hospital, No.199 Jiefang South Road, Quanshan District, Xuzhou, 221009, People's Republic of China.

Background: The aim of this study is to identify factors associated with the development of long-term severe tricuspid regurgitation (TR) following mitral valve replacement (MVR).

Methods: A retrospective analysis was conducted involving 308 patients who underwent single-valve MVR at Xuzhou Central Hospital between April 2017 and December 2022. Preoperative color Doppler ultrasound indicated that all patients had either no or mild to moderate tricuspid regurgitation.

View Article and Find Full Text PDF

Aims: This study compared echocardiography (echo) and cardiac computed tomography (CT) in measuring the Wilkins score and evaluated the potential added benefit of CT in predicting immediate percutaneous mitral valvuloplasty (PMV) outcomes in rheumatic mitral stenosis (MS) patients deemed eligible for PMV by echo.

Methods And Results: From a multicentre registry of 3,140 patients with at least moderate MS, we included 96 patients (age 56.4±11.

View Article and Find Full Text PDF

Purpose: We compared adults with mitral stenosis (MS) to 8 controls (CONT) to see how pulmonary impedance and wave reflections differ at baseline and after balloon valvuloplasty.

Methods: We separated the MS patients into groups according to mean pulmonary artery pressure: moderate (MOD; ≤ 26 mmHg, n = 21) and high (HIGH; > 26 mmHg, n = 33). We made baseline high-fidelity measurements in all patients, in the MS groups after vasodilation with nitroprusside, immediately and 4 months after balloon valvuloplasty.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!