A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rapid diagnosis of spinal muscular atrophy using denaturing high-performance liquid chromatography. | LitMetric

Rapid diagnosis of spinal muscular atrophy using denaturing high-performance liquid chromatography.

Zhonghua Yi Xue Yi Chuan Xue Za Zhi

Department of Neurology, First Affiliated Hospital, Fujian Medical University, Fuzhou, Fujian, 350005, PR China.

Published: June 2005

Objective: To introduce the application of denaturing high-performance liquid chromatography (DHPLC) in the diagnosis of childhood type spinal muscular atrophy (SMA).

Methods: Exon 7 and flanking area of survival motor neuron (SMN) gene were amplified by PCR in 1 standard sample, 25 normal individuals and 25 patients with SMA. The PCR products were then directly loaded onto the DHPLC system after denaturing and annealing. Different DNA segments were separated by changing the concentration of buffer A relative to that of buffer B.

Results: Different DNA segments were separable on the DHPLC chromatogram. Three peaks including SMN1/SMN2 heteroduplex peak, SMN2 homoduplex peak and SMN1 homoduplex peak were detected in 23 out of 25 normal individuals. Only SMN1 homoduplex peak was detected in 2 normal individuals and the standard sample, indicating the deletion of SMN2 On the contrary, only the SMN2 homoduplex peak was detected in 22 out of 25 patients with SMA, indicating deletion of SMN1. The three peaks as those of normal individuals were detected in the other 3 patients, indicating no SMN1 or SMN2 deletion.

Conclusion: As a new technology for diagnosing SMA, DHPLC is sensitive, accurate, rapid and convenient.

Download full-text PDF

Source

Publication Analysis

Top Keywords

normal individuals
16
homoduplex peak
16
peak detected
12
spinal muscular
8
muscular atrophy
8
denaturing high-performance
8
high-performance liquid
8
liquid chromatography
8
standard sample
8
patients sma
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!