Download full-text PDF |
Source |
---|
Oper Dent
January 2025
*Roberta Tarkany Basting, DDS, MSc, PhD, Professor, Restorative Dentistry Department, Faculdade São Leopoldo Mandic, São Paulo, Brazil.
This study evaluated the influence of six resin composite coating agents on color stability and surface roughness after toothbrushing abrasion. Discs (Ø6 mm x 2 mm) of nanofilled resin composite (Filtek Z350XT) were prepared for application of coating agents (n=10): control (absence), two surface sealants (PermaSeal and BisCover LV), two adhesive systems (Scotchbond Multi-Purpose Adhesive/3M Oral Care and Single Bond Universal), and two modeling liquids (Modeling Resin and Composite Wetting Resin). CIELab*, WID, and color change (ΔEab, ΔE00, and ΔWID) were analyzed at baseline, after finishing and polishing, after application of coating agents, after coffee staining (simulating 30 days and one year of staining), and after toothbrushing abrasion.
View Article and Find Full Text PDFInt J Implant Dent
January 2025
Lecturer at removable prosthodontic department, Faculty of dental medicine for Girls, Al-Azhar University, Cairo, Egypt.
J Vis Exp
December 2024
School of Engineering and Materials Science, Queen Mary University of London.
J Biomed Mater Res B Appl Biomater
January 2025
Dental Materials Unit, Center for Dental Medicine, Clinic for Masticatory Disorders and Dental Biomaterials, University of Zurich, Zurich, Switzerland.
The purpose of this study was to evaluate the characteristics of the ceramic bonding to cobalt-chromium (Co-Cr) alloys fabricated by casting, milling, and additive manufacturing, compared with zirconia and nickel-chromium. One hundred specimens (N = 100), prepared with the dimensions of 25 × 3 × 0.5 mm, were assigned to five groups (n = 20): presintered milled Co-Cr (Group M), additively manufactured Co-Cr (Group SLM), cast Co-Cr (Group C), presintered zirconia (Group Zi), and cast Ni-Cr (Group Ni).
View Article and Find Full Text PDFBiomicrofluidics
January 2025
School of Mechanical Engineering, Pusan National University, Busan, South Korea.
Monitoring platelet aggregation is crucial for predicting thrombotic diseases and identifying the risk of bleeding or resistance to antiplatelet drugs. This study developed a microfluidic device to measure platelet activation with high sensitivity. By controlling exposure time through repeated reinjections, the device enables the detection of subtle changes in platelet activity influenced by lifestyle factors, such as alcohol consumption.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!