Special polychlorinated biphenyls (PCBs) standards (native and isotope labeled) were analyzed by isotope dilution method using HRGC-HRMS. Multiple analysis of special PCBs standards by three different laboratories produced the relative response factors (RRFs) and relative standard deviations (RSDs %) was in the average of 0.979 and 3.86, respectively. Additionally, inter-laboratory analysis of various forms of transformer oil revealed the PCBs concentrations were in the following order; PCBs fortified transformer oil (940-1300 ng/g)>PCB polluted transformer oil (490-680 ng/g)>chemically degraded-transformer oil (480-490 ng/g) and PCBs free oil (ND-17 ng/g). Chemical degradation resulted in an order of magnitude decrease in the PCB concentrations. Specifically, higher chlorinated PCBs degraded into lower chlorinated PCBs. Also, composition of PCBs have been determined in PCB formulations from Japan (Kanechlor), Germany (Clophen), USA (Aroclor), Russia (Sovol) and Poland (Chlorofen). Major PCBs (24-PCB congeners) contributed 54-67%, 55-68%, 16-69%, 71% and 72% in Kanechlor, Clophen, Aroclor, Sovol and Chlorofen, respectively to total PCBs. The homologue pattern of Kanechlor, Aroclor and Clophen in technical fromulation was similar (e.g., Kanechlor-300 resembled to those of Clophen A-30 and Aroclor-1242). Furthermore, congener-specific distributions of major PCBs/dioxin-like PCBs and toxic equivalency quantities (TEQ) were calculated. Based on our tentative assumption calculations, cumulative production of five different technical PCB formulations, WHO-TEQ emission was estimated to be approximately 16.05 tons.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chemosphere.2005.04.034DOI Listing

Publication Analysis

Top Keywords

transformer oil
16
pcbs
12
pcb formulations
12
isotope dilution
8
polychlorinated biphenyls
8
biphenyls pcbs
8
pcbs standards
8
chlorinated pcbs
8
oil
6
dilution analysis
4

Similar Publications

Detecting dissolved gases in transformer oil is crucial for assessing the operational status of transformers. The gas composition in transformer oil can reflect the health status of the equipment and help identify potential failure risks in a timely manner. Based on density functional theory (DFT), Pd and Rh atoms were doped into the h-BN monolayer, and the most stable adsorption structures for each were first explored.

View Article and Find Full Text PDF

Open-closed single-tube on-beam tuning-fork-enhanced fiber-optic photoacoustic spectroscopy.

Photoacoustics

October 2024

Wuhan National Laboratory for Optoelectronics (WNLO) and National Engineering Research Center of Next Generation Internet Access-system, School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China.

A proof-of-concept on-beam tuning-fork-enhanced photoacoustic sensor based on an open-closed single-tube acoustic-microresonator (AmR) was proposed and investigated for the first time, to the best of our knowledge. Due to the high acoustic amplification effect, the open-closed AmR improved the detection sensitivity by 54 times with respect to the bare tuning fork (TF). Compared to traditional dual-tube/single-tube on-beam spectrophone configuration, the developed approach significantly facilitates the laser beam alignment and reduces the sensor size and gas consumption.

View Article and Find Full Text PDF

Kolmogorov-Arnold Network in the Fault Diagnosis of Oil-Immersed Power Transformers.

Sensors (Basel)

November 2024

Department of Communications, School of Electrical and Computer Engineering, University of Campinas, Campinas 13083-852, Brazil.

Instabilities in energy supply caused by equipment failures, particularly in power transformers, can significantly impact efficiency and lead to shutdowns, which can affect the population. To address this, researchers have developed fault diagnosis strategies for oil-immersed power transformers using dissolved gas analysis (DGA) to enhance reliability and environmental responsibility. However, the fault diagnosis of oil-immersed power transformers has not been exhaustively investigated.

View Article and Find Full Text PDF

Accurate assessment of the aging state of transformer oil-barrier insulation is crucial for ensuring the safe and reliable operation of power systems. This study presents the development of indoor accelerated thermal aging experiments to simulate the degradation of oil-immersed barrier insulation within transformers. A series of samples reflecting various aging states was obtained and categorized into six distinct groups.

View Article and Find Full Text PDF

Study on the Preparation and Test Method of Transformer Oil Used in Laboratory.

Materials (Basel)

December 2024

Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing 100191, China.

The power transformer is one of the most important parts of a power system. The transformer oil in a transformer not only increases its insulation strength, but also helps its cooling. Cellulose particles are one of the main factors affecting the breakdown characteristics of transformer oil, and the withstand voltage test can effectively detect the quality of transformer oil.

View Article and Find Full Text PDF