Purpose: To determine whether a cone-shaped interference screw positioned centrally during tibial fixation in hamstring anterior cruciate ligament (ACL) reconstruction was equal to or better than a peripheral position in terms of stiffness, yield load, ultimate load, and mode of failure.

Type Of Study: Randomized matched-pair biomechanical pullout study.

Methods: One of each of 7 matched pairs of human cadaveric tendon in porcine tibia with titanium cone-shaped screws were randomly allocated to either the peripheral or central group. Bone tunnels were drilled 45 degrees to the long axis of the tibia, akin to standard ACL reconstruction. Tunnel diameter was matched to tendon diameter and a screw 1 mm larger than tunnel diameter was inserted. A Universal Materials Testing Machine (Hounsfield Testing Equipment, Horsham, PA) was used to pull in the line of the tendon. Tendons were inspected after construct disassembly.

Results: The central screw configuration showed significantly higher stiffness (P = .0085), yield load (P = .0135), and ultimate load (P = .0075). The mode of failure in the peripheral screw position was slippage at the screw-tendon interface in all cases. In the central group, 87.5% of cases had a breakage in the tendon and 12.5% had slippage at the tendon-bone interface.

Conclusions: Central interference screw fixation of soft-tissue ACL reconstruction offers superior fixation strength and stiffness in single pullout mode when compared with peripheral interference screw fixation. Failure in the central group was mostly by tendon breakage, suggesting that a larger difference may be exhibited by the central over the peripheral fixation than demonstrated in this study.

Clinical Relevance: Central interference screw fixation compared with peripheral fixation may allow greater confidence in early rehabilitation and reduced clinical failure rates in the long term.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arthro.2005.03.004DOI Listing

Publication Analysis

Top Keywords

interference screw
16
acl reconstruction
12
central group
12
screw fixation
12
central
8
screw
8
hamstring anterior
8
anterior cruciate
8
cruciate ligament
8
yield load
8

Similar Publications

Background: Surgical techniques for biceps tenodesis vary in approach, fixation strategy, and anatomic location without clear superior technique for this common procedure.

Hypothesis/purpose: The purpose of this study was to prospectively evaluate a randomized cohort of patients undergoing arthroscopic suprapectoral (ASBT) with interference screw fixation using an inlay technique versus mini-open subpectoral (MOBT) with a unicortical button implant using an onlay technique with regards to 1) clinical outcome measures and 2) structural healing as evaluated by ultrasound.

Methods: From May 2017 to April 2021, patients undergoing biceps tenodesis were preoperatively randomized to either ASBT or MOBT.

View Article and Find Full Text PDF

Anatomic Distal Biceps Tendon Repair With All-Suture Cortical Buttons.

Arthrosc Tech

December 2024

Department of Orthopaedic Surgery, University of California Irvine, Orange, California, U.S.A.

Acute, traumatic distal biceps tendon ruptures are a common injury in the middle-aged athletic male population, with direct anatomic surgical repair being the most effective technique to restore maximal strength. Multiple techniques for distal biceps tendon repair have been described, including single- or dual-incision approaches and tendon fixation with cortical buttons, interference screws, suture anchors, and transosseous sutures. In this Technical Note, we demonstrate an anatomic distal biceps tendon repair technique with a single-incision approach using 2 all-suture cortical buttons.

View Article and Find Full Text PDF

Background: An all-inside endoscopic flexor hallucis longus (FHL) tendon transfer is indicated for the treatment of chronic, full-thickness Achilles tendon defects. The aim of this procedure is to restore function of the gastrocnemius-soleus complex while avoiding the wound complications associated with open procedures.

Description: This procedure can be performed through 2 endoscopic portals, a posteromedial portal (the working portal) and a posterolateral portal (the visualization portal).

View Article and Find Full Text PDF

Background: A lateral extra-articular tenodesis (LET) is increasingly being utilized to augment an anterior cruciate ligament reconstruction because it has been shown to reduce the risk of postreconstruction graft failure or recurrent rotatory instability. Various femoral fixation techniques are available, including the use of an interference screw, staple, or suture anchor.

Purpose: To determine and compare the biomechanical properties of an LET graft when using an interference screw, staple, or suture anchor for the femoral fixation for a modified Lemaire LET.

View Article and Find Full Text PDF