Purpose: We used four-dimensional multislice spiral computed tomography (MSCT) to determine respiratory lung-tumor motion and compared this strategy to common clinical practice in conformal radiotherapy treatment-planning imaging.

Methods And Materials: The entire lung volume of 10 consecutive patients with 14 lung metastases were scanned by a 16-slice MSCT. During the scans, patients were instructed to breathe through a spirometer that was connected to a laptop computer. For each patient, 10 stacks of 1.5-mm slices, equally distributed throughout the respiratory cycle, were reconstructed from the acquired MSCT data. The lung tumors were manually contoured in each data set. For each patient, the tumor-volume contours of all data sets were copied to 1 data set, which allowed determination of the volume that encompassed all 10 lung-tumor positions (i.e., the tumor-traversed volume [TTV]) during the respiratory cycle. The TTV was compared with the 10 tumor volumes contoured for each patient, to which an empiric respiratory-motion margin was added. The latter target volumes were designated internal-motion included tumor volume (IMITV).

Results: The TTV measurements were significantly smaller than the reference IMITV measurements (5.2 +/- 10.2 cm(3) and 10.1 +/- 13.7 cm(3), respectively). All 10 IMITVs for 2 of the 4 tumors in 1 subject completely encompassed the TTV. All 10 IMITVs for 3 tumors in 2 patients did not show overlap with up to 35% of the corresponding TTV. The 10 IMITVs for the remaining tumors either completely encompassed the corresponding TTV or did not show overlap with up to 26% of the corresponding TTV.

Conclusions: We found that individualized determination of respiratory lung-tumor motion by four-dimensional respiratory-gated MSCT represents a better and simple strategy to incorporate periodic physiologic motion compared with a generalized approach. The former strategy can, therefore, improve common and state-of-the-art clinical practice in conformal radiotherapy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijrobp.2005.03.002DOI Listing

Publication Analysis

Top Keywords

conformal radiotherapy
12
four-dimensional multislice
8
computed tomography
8
determination respiratory
8
respiratory lung-tumor
8
lung-tumor motion
8
motion compared
8
clinical practice
8
practice conformal
8
respiratory cycle
8

Similar Publications

Adaptive radiotherapy (ART) provides greater benefits than intensity-modulated radiotherapy (IMRT) regarding dosimetric outcomes in patients with cervical cancer. To investigate the clinical benefits of ART, we have collected data from 115 cervical cancer patients who underwent radical radiotherapy at our institution. Fifty-nine patients received a single course of IMRT.

View Article and Find Full Text PDF

Purpose: In this retrospective study, we aimed to evaluate the efficacy and incidence of radiation-induced brain necrosis (RBN) after volumetric modulated arc therapy-based stereotactic irradiation (VMAT-STI) for brain metastases.

Methods: In the 220 brain metastatic lesions included between January 2020 and June 2022, there were 1-9 concurrently treated lesions (median 1). A biologically effective dose (BED)10 of 80 Gy and a reduced BED10 of 50 Gy were prescribed to the gross tumor volume (GTV) and planning target volume (PTV) (PTV = GTV + 3 mm) margins, respectively.

View Article and Find Full Text PDF

intra-arc binary collimation (iABC) is a novel treatment technique in which dynamic conformal arcs are periodically interrupted with binary collimation. It has demonstrated its utility through planning studies for the treatment of multiple metastases. However, the binary collimation approach is idealized in the planning system, while the treatment deliveries must adhere to the physical limitations of the mechanical systems involved [e.

View Article and Find Full Text PDF

Accelerated partial breast irradiation (APBI) represents a valid option for adjuvant therapy of selected early breast cancer (BC). This single-institution prospective randomized study compares the health-related quality of life (HRQoL) between women treated with the highly conformal-external beam APBI technique and those with the more commonly used moderately hypofractionated whole breast irradiation (hypo-WBI). Eligible patients were women over 50 years with early BC (G1/2 DCIS ≤ 25 mm or G1/2 invasive non-lobular luminal-like HER2 negative carcinoma ≤ 20 mm) after breast-conserving surgery with negative margins.

View Article and Find Full Text PDF

Introduction: Diffuse intrinsic pontine gliomas are associated with dismal survival outcomes. Conventional fractionation radiation to a dose of 60 Gy is the standard of treatment. This retrospective review aims to compare survival and toxicity outcomes of patients treated with conventional fractionation (CF) and hypofractionation (HF) radiotherapy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!