A novel automated rat catalepsy bar test system based on a RISC microcontroller.

J Neurosci Methods

Departamento de Neurociencias, Centro de Investigaciones Regionales Dr. Hideyo Noguchi, Universidad Autónoma de Yucatán, 97000 Mérida, Yucatán, México.

Published: July 2005

Catalepsy tests performed in rodents treated with drugs that interfere with dopaminergic transmission have been widely used for the screening of drugs with therapeutic potential in the treatment of Parkinson's disease. The basic method for measuring catalepsy intensity is the "standard" bar test. We present here an easy to use microcontroller-based automatic system for recording bar test experiments. The design is simple, compact, and has a low cost. Recording intervals and total experimental time can be programmed within a wide range of values. The resulting catalepsy times are stored, and up to five simultaneous experiments can be recorded. A standard personal computer interface is included. The automated system also permits the elimination of human error associated with factors such as fatigue, distraction, and data transcription, occurring during manual recording. Furthermore, a uniform criterion for timing the cataleptic condition can be achieved. Correlation values between the results obtained with the automated system and those reported by two independent observers ranged between 0.88 and 0.99 (P<0.0001; three treatments, nine animals, 144 catalepsy time measurements).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jneumeth.2005.01.018DOI Listing

Publication Analysis

Top Keywords

bar test
12
automated system
8
novel automated
4
automated rat
4
catalepsy
4
rat catalepsy
4
catalepsy bar
4
system
4
test system
4
system based
4

Similar Publications

In the frame of developing a sustainable chemical industry, heterogeneously catalyzed CO2 hydrogenation to methanol has attracted considerable interest. However, the Cu-Zn based catalyst system employed in this process is very dynamic, especially in the presence of the products methanol and water. Deactivation needs to be prevented, but its origin and mechanism are hardly investigated at high conversion where product condensation is possible.

View Article and Find Full Text PDF

Unlabelled: We investigated the impact of participation in post-secondary university education (PSE) on the academic knowledge of adult students with severe intellectual disability and extensive support needs (SIDESN) vs. a similar group of controls who did not participate in PSE. We also examined whether the PSE would result in a "near transfer" to basic crystallized (facts and information) and fluid (problems involving executive functions and working memory) cognitive abilities, the contribution of background characteristics and crystallized and fluid abilities to their academic knowledge, semantic fluency and temporal relations.

View Article and Find Full Text PDF

Optimization of In-Situ Growth of Superconducting Al/InAs Hybrid Systems on GaAs for the Development of Quantum Electronic Circuits.

Materials (Basel)

January 2025

CNR-IOM-Istituto Officina dei Materiali, Consiglio Nazionale delle Ricerche, 34149 Trieste, Italy.

Hybrid systems consisting of highly transparent channels of low-dimensional semiconductors between superconducting elements allow the formation of quantum electronic circuits. Therefore, they are among the novel material platforms that could pave the way for scalable quantum computation. To this aim, InAs two-dimensional electron gases are among the ideal semiconductor systems due to their vanishing Schottky barrier; however, their exploitation is limited by the unavailability of commercial lattice-matched substrates.

View Article and Find Full Text PDF

Design and Application of Uniaxially Sensitive Stress Sensor.

Micromachines (Basel)

January 2025

State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Chengdu 611731, China.

Current stress sensors for microsystems face integration challenges and complex signal decoding. This paper proposes a real-time uniaxially sensitive stress sensor. It is obtained by simple combinations of bar resistors using their sensitivity differences in different axes.

View Article and Find Full Text PDF

Cardiopulmonary Impact of the Minimally Invasive Repair of Pectus Excavatum in Pediatric patients: A Prospective Pilot Study.

J Pediatr Surg

January 2025

Division of Pediatric Surgery, Department of Surgery, Phoenix Children's, Phoenix, AZ, USA; Department of Child Health and Development, University of Arizona, School of Medicine, Phoenix, AZ, USA.

Introduction: The physiologic benefits of the minimally invasive repair of pectus excavatum (MIRPE) on cardiopulmonary function are poorly understood in pediatrics. We sought to examine the effects of MIRPE on exercise response during cardiopulmonary exercise testing (CPET).

Methods: A prospective-pilot study was conduct of patients ≤18 years who presented for pectus bar removal.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!