Measuring the porosity of materials by digital image analysis of micrographs is a well-established and convenient method for the testing of metallic samples. However, when applied to ceramic materials, this method has been shown to be much less reliable and poorly reproducible. The purpose of this present work is to clarify the reason for this deficiency, involving many porosity measurements, performed on plasma-sprayed zirconia, under systematically varied microscopic imaging conditions, and the porosities being calculated using various evaluation methods. Comparison between of the results has shown that the present state of the image analysis method is not satisfactory for absolute porosity measurements on ceramic materials. It can be useful as a convenient tool for comparative measurements, however, if the imaging conditions maintained in the microscope and the evaluation method are held to be exactly identical.