Problems with film processing in medical X-ray imaging in Lithuania.

Radiat Prot Dosimetry

Radiation Protection Centre, Kaunas department, Kaunas, Lithuania.

Published: September 2005

Optimisation in X-ray imaging in order to reduce patient doses during diagnostic X-ray examinations is a complex process given the high level of image quality required. When quality systems are implemented as a basis for optimisation, attention should be paid to the qualifications of the staff and quality control of the equipment and of the X-ray imaging procedures, as well as to the methods used to evaluate the quality of these procedures. Until recently, quality control procedures at health care institutions in Lithuania were limited to the testing of X-ray units. Since film processing is one of the most important factors influencing patient doses and image quality during X-ray examinations, in 2003 the Kaunas department of the Radiation Protection Centre organised inspections of film processing laboratories in 11 health care institutions-hospitals and outpatient departments-in the Kaunas region. Problems of non-compliance with requirements identified during these inspections are discussed in this paper. Most of the health care institutions inspected already had quality assurance programmes. However, the implementation of these programmes was sometimes erratic because of the insufficient attention paid to the film developing processes. The worst situation was found in 4 institutions where the films were developed manually. Only 3 of the 11 departments inspected had sensitometers and densitometers for quality control of the processing. In many cases there was no control of chemicals, film sensitivity and density, or else control was irregular. In only a few departments were the effects of repeated controls investigated and discussed. Despite the current problems occurring in medical X-ray diagnostic departments in Lithuania, the situation is rapidly improving. New equipment is being installed, new devices for quality control are being used and, last but not least, the view of hospital administrators, radiologists and laboratory workers towards quality assurance and quality control is changing.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/nch577DOI Listing

Publication Analysis

Top Keywords

quality control
20
film processing
12
x-ray imaging
12
health care
12
quality
11
medical x-ray
8
patient doses
8
x-ray examinations
8
image quality
8
attention paid
8

Similar Publications

Introduction: Although there are numerous options for epilepsy treatment, its effective control continues unsatisfactory. Thus, search for alternative therapeutic options to improve the efficacy/safety binomial of drugs becomes very attractive to investigate. In this context, intranasal administration of antiseizure drugs formulated on state-of-the-art nanosystems can be a promising strategy.

View Article and Find Full Text PDF

Purposes: This meta-analysis aims to systematically analyze the efficacy of low-level red light (LRL) therapy for myopia control and prevention in children.

Methods: All the data were searched from the PubMed, EMBASE, and the Cochrane Library. The Cochrane Handbook was used to evaluate the quality of the included studies.

View Article and Find Full Text PDF

A Unified Approach to Health Data Exchange: A Report From the US DHHS.

JAMA

January 2025

Assistant Secretary for Technology Policy/Office of the National Coordinator for Health IT, Washington, DC.

Importance: Health information technology, such as electronic health records (EHRs), has been widely adopted, yet accessing and exchanging data in the fragmented US health care system remains challenging. To unlock the potential of EHR data to improve patient health, public health, and health care, it is essential to streamline the exchange of health data. As leaders across the US Department of Health and Human Services (DHHS), we describe how DHHS has implemented fundamental building blocks to achieve this vision.

View Article and Find Full Text PDF

Male infertility is a common complication of diabetes. Diabetes leads to the decrease of zinc (Zn) content, which is a necessary trace element to maintain the normal structure and function of reproductive organs and spermatogenesis. The purpose of this study was to investigate the effect of metformin combined with zinc on testis and sperm in diabetic mice.

View Article and Find Full Text PDF

Background: Infertility is a significant issue in spinal cord injury (SCI) patients. Men with SCI often experience erectile and ejaculatory dysfunctions, and low sperm quality leading to impaired fertility. In this study, we investigated the effectiveness of Erythropoietin (EPO)alginate/chitosan (CH-AL) hydrogel on SCI-induced male rat infertility.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!