A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mechanical devices for cardiopulmonary resuscitation. | LitMetric

Mechanical devices for cardiopulmonary resuscitation.

Curr Opin Crit Care

Division of Emergency Medicine, The University of Texas Southwestern Medical Center, Dallas, Texas 75390-8579, USA.

Published: June 2005

Purpose Of The Review: For over 40 years, manual chest compressions have been the foundation of cardiopulmonary resuscitation and recent studies have clearly reconfirmed the hemodynamic significance of delivering consistent, high-quality, infrequently-interrupted chest compressions. However, there remain multiple inadequacies in the actual delivery of manual chest compressions during cardiopulmonary resuscitation. One potential solution is use of adjunct mechanical devices.

Recent Findings: Two different methods of accessory chest compression techniques recently have demonstrated enhanced short-term survival. The active compression-decompression device is a hand-held, manually operated suction device applied to the center of the chest wall. In tandem with an impedance threshold (airway) device, active compression-decompression has shown a 65% improvement in 24-hour survival rates (compared with standard cardiopulmonary resuscitation) in a randomized out-of-hospital clinical trial (n = 210). The second device, called Auto-Pulse CPR is an automated machine that uses a load-distributing, broad compression band that is applied across the entire anterior chest. A recent out-of-hospital retrospective case-control study (n = 162) also revealed improved short-term survival.

Summary: High quality chest compressions during cardiopulmonary resuscitation are critical elements in effecting successful resuscitation following a cardiac arrest. Recent studies utilizing adjunct mechanical devices have not only revealed significant increases in the effectiveness of chest compressions, including improved hemodynamics in both animal models and human studies, but also improvements in short-term human survival in the clinical setting. It is hoped that these promising findings will eventually be corroborated in terms of improved neurologically intact, long-term patient survival. Clinical trials are currently underway to validate such efficacy.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.ccx.0000163720.23558.36DOI Listing

Publication Analysis

Top Keywords

cardiopulmonary resuscitation
20
chest compressions
20
mechanical devices
8
chest
8
manual chest
8
compressions cardiopulmonary
8
adjunct mechanical
8
active compression-decompression
8
survival clinical
8
resuscitation
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!