The limit of photoreceptor sensitivity: molecular mechanisms of dark noise in retinal cones.

J Gen Physiol

Keck Center for Theoretical Neurobiology and Department of Physiology, School of Medicine, University of California at San Francisco, 94143, USA.

Published: June 2005

AI Article Synopsis

  • Detection threshold in cone photoreceptors relies on multiple photon absorptions due to small amplitude of single photon photocurrents, which are overshadowed by dark noise.
  • Dark noise results from fluctuating cytoplasmic levels of cGMP and Ca(2+), driven by the activity of guanylate cyclase and phosphodiesterase in the dark.
  • A mathematical model based on phosphodiesterase dynamics reveals that fish cones have a shorter active PDE lifetime (~55 ms) compared to nonmammalian rods (~555 ms), explaining why cones are noisier and less light sensitive.

Article Abstract

Detection threshold in cone photoreceptors requires the simultaneous absorption of several photons because single photon photocurrent is small in amplitude and does not exceed intrinsic fluctuations in the outer segment dark current (dark noise). To understand the mechanisms that limit light sensitivity, we characterized the molecular origin of dark noise in intact, isolated bass single cones. Dark noise is caused by continuous fluctuations in the cytoplasmic concentrations of both cGMP and Ca(2+) that arise from the activity in darkness of both guanylate cyclase (GC), the enzyme that synthesizes cGMP, and phosphodiesterase (PDE), the enzyme that hydrolyzes it. In cones loaded with high concentration Ca(2+) buffering agents, we demonstrate that variation in cGMP levels arise from fluctuations in the mean PDE enzymatic activity. The rates of PDE activation and inactivation determine the quantitative characteristics of the dark noise power density spectrum. We developed a mathematical model based on the dynamics of PDE activity that accurately predicts this power spectrum. Analysis of the experimental data with the theoretical model allows us to determine the rates of PDE activation and deactivation in the intact photoreceptor. In fish cones, the mean lifetime of active PDE at room temperature is approximately 55 ms. In nonmammalian rods, in contrast, active PDE lifetime is approximately 555 ms. This remarkable difference helps explain why cones are noisier than rods and why cone photocurrents are smaller in peak amplitude and faster in time course than those in rods. Both these features make cones less light sensitive than rods.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2234084PMC
http://dx.doi.org/10.1085/jgp.200509277DOI Listing

Publication Analysis

Top Keywords

dark noise
20
rates pde
8
pde activation
8
active pde
8
pde
7
dark
6
cones
6
noise
5
limit photoreceptor
4
photoreceptor sensitivity
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!