A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Albumin and hydroxyethyl starch 130 kDa/0.4 improve filter clearance and haemocompatibility in haemo- and plasmafiltration--an in vitro study. | LitMetric

Background: Apart from their standard applications, haemofiltration (HF) and plasmafiltration (PF) may provide helpful therapy for sepsis, multiple organ- and acute liver-failure. Some colloids cause either decreases or increases in blood cell agglomeration. We hypothesized that solutions which reduce cell aggregability may lead to both improved filter clearance and better haemocompatibility due to decreasing rates of clogged hollow fibres.

Methods: Heparinized porcine blood (5 IU/ml) was used in an in vitro circuit. The filter types tested were from GAMBRO: HF66D (effective membrane surface: 0.6 m2) and PF1000N (effective membrane surface: 0.15 m2). Albumin (ALB), hydroxyethyl starch (HES) 200/0.5, HES 130/0.4, gelatin (GEL) or normal saline (0.9%) were added to the blood (n = 6/group). Recirculation systems were run for 2 h. Spontaneous haemolysis and filter resistance >420 mmHg were selected as indications of maximal flow rates. Sieving coefficients were determined for 17 parameters at the lowest and highest blood flows and filtration rate.

Results: Based on the filter types used, supplementation of ALB and HES130/0.4 led to an improved filter clearance without increasing the number of clogged capillary membranes or causing impaired haemocompatibility. Sieving coefficients for most solutes were independent of volume substitute and flow rate. Haemocompatibility and filter clearance deteriorated after addition of HES200 or GEL to the blood.

Conclusions: Under standardized in vitro conditions, we found that colloids which reduce cell aggregability cause improved HF- and PF-performance. This phenomenon may provide new options for higher clearances and may lead to new concepts in low dose anticoagulation.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ndt/gfh913DOI Listing

Publication Analysis

Top Keywords

filter clearance
16
hydroxyethyl starch
8
reduce cell
8
cell aggregability
8
improved filter
8
filter types
8
effective membrane
8
membrane surface
8
sieving coefficients
8
filter
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!