A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Freedom from atrial tachyarrhythmias after catheter ablation of atrial fibrillation: a randomized comparison between 2 current ablation strategies. | LitMetric

Background: Data on the comparative value of the circumferential pulmonary vein and the segmental pulmonary vein ablation for interventional treatment of atrial fibrillation are limited. We hypothesized that the circumferential pulmonary vein ablation approach was superior to the segmental pulmonary vein ablation approach.

Methods And Results: One hundred patients with highly symptomatic atrial fibrillation were randomly assigned to undergo either circumferential (n=50) or segmental pulmonary vein ablation (n=50). Freedom from atrial tachyarrhythmias in a 7-day Holter monitoring at 6 months was the primary end point. Secondary end points were freedom of arrhythmia-related symptoms and a composite of pericardial tamponade, thromboembolic complications, and pulmonary vein stenosis (safety end point). On the basis of the results of the 7-day Holter monitoring at 6 months, 21 patients (42%) after circumferential pulmonary vein ablation and 33 patients (66%) after segmental pulmonary vein ablation (P=0.02) were free of atrial tachyarrhythmia episodes. During the 6-month follow-up period, 27 patients (54%) after circumferential pulmonary vein ablation and 41 patients (82%) after segmental pulmonary vein ablation remained free of arrhythmia-related symptoms (P<0.01). No significant difference was found in the safety end point (6 versus 7 events; P=0.77) in the circumferential versus segmental pulmonary vein ablation group, respectively.

Conclusions: This study demonstrates no superiority of the circumferential pulmonary vein ablation over segmental pulmonary vein ablation for treatment of atrial fibrillation in terms of efficacy and safety.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCULATIONAHA.104.491530DOI Listing

Publication Analysis

Top Keywords

pulmonary vein
40
vein ablation
32
segmental pulmonary
20
circumferential pulmonary
16
atrial fibrillation
12
ablation
10
pulmonary
10
vein
10
freedom atrial
8
atrial tachyarrhythmias
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!