Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The double antigen bridging immunoassay has been used extensively for detection of immunogenicity responses to therapeutic monoclonal antibodies. We have analyzed parameters affecting performance of this type of immunoassay including microtiter plate antigen coating concentration, enzyme-labeled antigen conjugate dilution and assay format (one-step versus two-step). We present results demonstrating that the format of the assay has a significant impact on the optimal parameters to maximize assay performance. A one-step assay format achieves maximal sensitivity across a broad range of coating concentrations and at a lower concentration of conjugate than that in a two-step format. In contrast, a two-step format requires very low coating concentrations and higher conjugate concentrations to achieve maximal sensitivity and suffers from significantly reduced sensitivity at higher coating concentrations. Together, these findings indicate that a one-step assay format can greatly reduce the effect of coating concentration variation on assay performance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpba.2005.03.037 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!