A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Correction of systematic setup errors in prostate radiation therapy: how many images to perform? | LitMetric

The purpose of this study was to develop an evidence-based off-line setup correction protocol for systematic errors in prostate radiation therapy. Daily orthogonal electronic portal images were acquired from 30 patients. Field displacements were measured in the medial-lateral (ML), superior-inferior (SI), and anterior-posterior (AP) directions for each treatment fraction. The off-line protocol corrects the mean field displacement found from n consecutive images, starting at a particular fraction of treatment, with a fixed tolerance level. Simulations were performed with the measured data to determine (1) how many images (n) should be averaged to determine the systematic error; (2) on which treatment fraction should the protocol be initiated; and (3) what tolerance level should be applied to determine whether the patient position should be corrected. Uncorrected systematic errors in the ML, SI, and AP directions were (mean position +/- 1 standard deviation [SD]): -0.7 +/- 2.2 mm, -1.5 +/- 1.3 mm, and 1.4 +/- 2.6 mm, respectively. Random errors (1 SD and range) were 1.9 mm (1.3 - 3.3), 1.5 mm (0. - 4.1), and 1.8 mm (1.0-2.6), respectively. A correction based on a single image taken on the first fraction actually increased the systematic errors in the ML and SI directions compared with no correction. More accurate correction of systematic errors was achieved with increasing number of images averaged, with only small benefit after 5 images. With fewer images averaged, delaying the start of the protocol resulted in more accurate correction because of the influence of unrepresentative positions at early fractions. The number of corrections made on patients with small (< 2 mm) systematic errors was minimized for tolerance values of 2 mm and n > or = 5 images averaged. The optimal off-line setup correction protocol would be to shift the patient by the mean displacement of the first 5 portal images of a radical course of radiation therapy. A small tolerance level should be utilized with 2 mm giving good accuracy with minimal unnecessary shifts.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.meddos.2005.03.003DOI Listing

Publication Analysis

Top Keywords

systematic errors
20
images averaged
16
radiation therapy
12
tolerance level
12
images
9
correction systematic
8
errors prostate
8
prostate radiation
8
off-line setup
8
setup correction
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!