The purpose of this prospective, randomized study was to compare the venous blood levels of lidocaine and heart rate changes after intraosseous and infiltration injections of 1.8 ml of 2% lidocaine with 1:100,000 epinephrine. Using a crossover design, 20 subjects randomly received an intraosseous and infiltration injection at two separate appointments. The heart rate was measured using a pulse oximeter. Venous blood samples were collected before the injections and at 2, 5, 10, 15, 20, 25, 30, 45, and 60 min after the injections. The blinded plasma samples were analyzed for lidocaine concentrations using high-performance liquid chromatography (HPLC). The intraosseous injection resulted in a statistically significant increase in heart rate, when compared to the infiltration injection, during solution deposition and for 2 min after the injection. The plasma levels of lidocaine were not statistically different for maxillary anterior intraosseous and infiltration injections when using 1.8 ml of 2% lidocaine with 1:100,000 epinephrine.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.don.0000148146.10314.1a | DOI Listing |