Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A simple, rapid and sensitive LC-MS/MS bioanalytical method has been developed to simultaneously quantify Camptosar (CPT-11) and its active metabolite, SN-38, in mouse plasma and tissues. A single step protein precipitation with acetonitrile in 96-well plates was used for sample preparation. Camptothecin (CPT) was used as the internal standard. Fast separation of SN-38, CPT-11 and CPT was carried out isocratically on a C18, 2 mm x 50 mm, 5 microm HPLC column with a mobile phase containing acetonitrile and 20 mM ammonium acetate (pH 3.5) and a 2.5 min chromatographic run time. The API 4000 MS/MS system was operated in positive ionization multiple reaction monitoring mode, and the transitions for SN-38, CPT-11 and CPT were 393.4 --> 349.3, 587.6 --> 167.2 and 349.3 --> 305.3, respectively. The SN-38 and CPT-11 concentrations in samples were calculated from a standard curve of peak area ratios of the analyte to that of the internal standard using a 1/chi2 weighted linear regression. The quantitation limit of 0.5 ng/mL was achieved by using a low sample volume (100 microL) of plasma or tissue homogenates. The assay was linear over the concentration range of 0.5-500 ng/mL with acceptable precision and accuracy. The method was used for the quantification of CPT-11 and SN-38 in plasma and tissues to support a preclinical pharmacokinetics and tissue distribution study of CPT-11 in mice.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2004.08.060 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!